![Ugolini DELICE Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/ugolini/delice-series/delice-series_operators-manual_3274914015.webp)
17
Heating element not hot
Heating element burned out
R e p l a c e t h e h e a t i n g
element
The maximum temperature
thermostat (located under the
distributor) is set too low
Regolarlo alla temperatura
opportuna
Thermal fuse burned out
Adjust it to a suitable
temperature
Thermal fuse burned out
Thermal fuse defective
Replace with a good one
Maximum temperature
thermostat doesn't intervene
R e p l a c e m a x i m u m
temperature thermostat
I'm not getting a suffi-
ciently dense product
The temperature of the
service thermostat (located on
the side of the distributor) is
set too low
A d j u s t i t t o a s u i t a b l e
temperature
The maximum temperature
thermostat (located under the
distributor) is set too low
A d j u s t i t t o a s u i t a b l e
temperature
Product excessively diluted
Increase the concentration
of the product
I'm not getting a suffi-
ciently hot product
The temperature of the
service thermostat (located on
the side of the distributor) is
set too low
A d j u s t i t t o a s u i t a b l e
temperature
The bottom of the tub is not
touching the heating element
Position the tub on the
heating element correctly
PROBLEM
CAUSE
SOLUTION