OPERATION
COMET
USER
GUIDE
16
0-10
V
OPERATION
All Comet models in the range can be 0-10V (current source) controlled as described in the
Programmable Function Table and as detailed in the following sections
For all 0-10V current source operation modes the luminaire must be set to 0-10V in the Control
Mode sub menu.
Control mode
MENU
>>
>>
SCROLL
UP/DOWN
>>
ENTER
Control mode
0
10V
CHAN
No.
FUNCTION
0
10V
VALUE
DESIRED
EFFECT
01
LED
Dimming
0V to 10V
No light output to full light output
02
Wheel Control
0V
Wheel at rest at cutout – full light output
02
Wheel Control
0.02V to
4.9V
Wheel indexing. Each increment moves wheel
around one se
tti
ng and stops. 0.02 to 4.9V = one
full rota
ti
on
02
Wheel Control
5V to 7.49V
Clockwise rota
ti
on of wheel from fast to slow
02
Wheel Control
7.5V to 10V An
ti
clockwise rota
ti
on of wheel from slow to fast
0-10V CHANNELS
NOTE:
This is a current source 0-10V control system. For this control mode to work, the Comet
requires a varying control voltage input (between 0 and 10V DC) from a 0-10V controller (source)
to control the dimming or decorative wheel motors, or both if two 0-10V channels are used.
If no 0-10V control voltage is present on the dimming input the LED will not illuminate.
If no 0-10V control voltage is present on the motor input the wheel will not turn but may twitch
slightly.
Содержание Comet Light Source
Страница 23: ...NOTES 23 UFO LIGHTING ...