Log Navigation Menu Options

TEMPERATURE TESTING

Select the Temperature Rotary Dial position.

Temperature Display

Viewing/Printing 

Press 

 BUTTON to print the Temperature Screen.

Print the currently selected Log

Navigate to the nex

t

 available Log of the selected type (Option will only 

appear if there is more than one Log).

Navigate to the previously selected Log of the selected type (Option will 

only appear if there is more than one Log).

Exit back to the previous menu.

STATUS

FLUE 1

AUX

FLUE 2

TEMP

Combu

stion Analy

zer

C161

CO

  C

O2

  T

EM

P

Pressure will only show if fitted

Use the T1 connection for the Supply temperature sensor.

Use the T2 connection for the Return temperature sensor.

Real time temperature difference

Содержание C161C

Страница 1: ...40 Fax 503 643 6322 www ueitest com Email info ueitest com INSTRUCTION MANUAL ENGLISH Residential Combustion Analyzer Combustion Analyzer C161 CO C O 2 T E M P Status v3 Aux O2 Eff CO CO2 Temp Exch Te...

Страница 2: ...yout 10 Status Bar Menu Options 10 Status Bar Options Table 10 Menu 11 Using the Menu 11 Stored Logs Memory 12 Menu Options 12 Viewing Stored Logs 13 Log View Menu Options 13 Navigating Stored Logs 13...

Страница 3: ...o are familiar with the hazards of their trade Observe all recommended safety procedures that include proper lockout utilization and use of personal protective equipment that includes safety glasses g...

Страница 4: ...odule is fitted K Down Button Short press to navigate DOWN L ENTER Button Short press select current option displayed Long press to activate some menu items M Rotary Selector Dial N Particle Filter in...

Страница 5: ...3 Aux O2 Eff CO CO2 Temp Exch Test Serial No Sensors Fitted CO CO2 NO O2 T2 T1 B C D E F G H I J K L M W V X P O N S U T R Q Flue Probe Temperature Plug Plugs into T1 Narrow Pin MUST be on the Right h...

Страница 6: ...PRE TEST CHECKLIST SETTING INLET TEMPERATURE ANALYZER CONNECTIONS Turn on and zero the analyzer without the flue probe connected to use ambient temperature Connect flue probe thermocouple to T1 during...

Страница 7: ...o CO2 Zero On the Purge option short press the Edit Button and a 60 second Purge will begin STATUS F L U E 1 AUX FLUE 2 T E M P P EMPTYING CLEANING THE IN LINE WATER TRAP CHANGING THE PARTICLE FILTER...

Страница 8: ...fgc except for Heavy Oil and Pellets O2 Ref Selectable parameter select between 0 0 to 20 0 Logs if logs are saved they will be displayed Code for Authorized Service Personnel only Status Screen Ti Am...

Страница 9: ...G Butane Propane Natural Gas Bio Oil Ambient temperature around the analyzer Current atmospheric pressure mBar Shows number of days until next calibration is due Status Bar User Interface The large si...

Страница 10: ...Status Bar will offer the user Menu items based on the Selector Dial setting Status Bar Options Table Test Screen Dial Digital Position Test Screen Status Info Available STATUS AUX O2 Eff CO CO2 TEMP...

Страница 11: ...ess and buttons to change field contents Press to enter content selected Menu Items MENU Sub Menu OPTIONS COMMENTS Time HH MM SS 24 Hour Format e g 7AM 0 00 00 7PM 19 00 00 Date DD MM YY Header LINE 1...

Страница 12: ...sage status simply navigate to menu LOGS press the button to select the Log desired Number of stored Combustion Logs Number of stored Auxiliary Logs Number of stored Temperature Logs and Pressure if f...

Страница 13: ...ll be displayed Log Number Log time and date this line will alternate between time and date of Log Log readings information is specific to Log type Navigation Menu options STATUS F L U E 1 AUX FLUE 2...

Страница 14: ...of the selected type Option will only appear if there is more than one Log Navigate to the previously selected Log of the selected type Option will only appear if there is more than one Log Exit back...

Страница 15: ...k gas and an increase in the Excess Air In some sealed systems the fresh air drawn in through the breach may reduce the combustion air available leading to an increase in the CO reading If either of t...

Страница 16: ...PRINT BUTTON again UEi Infrared Printer Make sure the printer is switched on ready to accept data and its infrared receiver is in line with the analyzer s infrared emitter on top of the analyzer Combu...

Страница 17: ...1 3 in accordance to 1st German Feder al Emission Control Ordinance Bim5chV Operating Conditions Temperatures Humidity 32 to 113 F 0 to 45 C 15 to 90 RH non condensing Power Supply Rechargeable batte...

Страница 18: ...rs Draft Verify proper combustion O2 CO2 CO Stack Temp Efficiency Hi Low fire Gas Pressure Supply and Return Water temp 80 Furnace Verify proper combustion O2 CO2 CO Stack Temp Vent Pressure Efficienc...

Страница 19: ...atic Duct Pressure Temperature Rise AC side Static Pressure Drop across coils WHAT RESULTS ARE GENERALLY ACCEPTABLE What Results Are Generally Acceptable Atmospheric Gas Fixed Burners Gas Fired Burner...

Страница 20: ...s can degrade electronic circuits Whenever practical keep the instrument away from dust and dirt that can cause premature wear Although your instrument is built to withstand the rigors of daily use it...

Страница 21: ...the protective rubber boot and fit 3 AA NiMH rechargeable batteries in the battery compartment Take great care to ensure they are fitted with the correct battery polarity Replace the battery cover an...

Страница 22: ...ombustion analyzers have a standard 1 year warranty Each recertification extends the warranty for 1 more year for up to 10 years from the date of purchase Contractors who book recertification of a C16...

Страница 23: ...measure the CO2 level and the stack temperature and then reference a slide scale that would give you the relative efficiency number UEi s electronic combustion analyzers perform the measurements on a...

Страница 24: ...red or replaced at UEi s option This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration tampering accident misuse abuse neglect or i...

Отзывы: