Technical information
english
C
Technical information
EN-45
Serial number:
On the unit there is a serial number SN that clearly
identifies the unit.
Battery:
CR2033
Size:
153mm (L) x 31mm (W) x 40mm (H)
Weight:
53g (with battery), 50g (without battery)
Technical data
3.
Type:
Infrared ear thermometer free of protective cover
Measuring range:
0°C to 100.0°C (32.0°F to 212.0°F)
Measuring
accuracy:
Medical sector:
35.0°C to 42.0°C±0.2°C
95°F to 107.6°F ±0.4°F
Measuring
accuracy:
Outside the medical sector:
0°C to 32°C as well as 42°C to 100°C ±1.0°C
32°F to 89.6°F as well as 107.6°F to 212°F ±33.8°F
32°C to 34.9°C as well as 42°C to 42.2°C ±0.3°C
89.6°F to 94.8°F as well as 107.6°F to 108°F ±0.6°F
Display:
Liquid crystal display with display unit 0.1°C (0.1°F)
Beep signals:
a. 1 short acoustic signal: The unit is switched ON and
ready for measurement.
b. 1 long acoustic signal (1 s.): Measuring process
completed if the measured value is under 37.5°C
(99.4°F). 10 short acoustic signals: If the measured
value is higher than or equals 37.5°C (99.4°F).
c. 3 short acoustic signals: System error or malfunction.
Memory:
a. Value last measured appears as soon as unit is
switched on.
b. 12 measurements by memory call
Ambient operating
conditions:
6°C to 40°C (41.0°F to 104°F)
Rel. air humidity 15% - 95%
Storage and trans-
port conditions:
-25°C to 55°C (-13°F to 131°F)
Rel. air humidity 15% - 95%
Automatic
switch-off:
About 1 minute after the last measurement. The unit
switches off automatically to protect against misuse.
A metrological control is generally recommended every 2 years. However, in
Germany, expert users are required to do so according to the „Medizinprodukte-
Betreiberverordnung“ [medical devices operator ordinance].
It can be performed either by the UEBE Medical GmbH, by an authority responsible
for metrology or by authorised maintenance services. Please refer to your national
requirements.
Important:
Without the manufacturer‘s consent, no changes may be made on
this unit (e.g. opening of the unit other than for battery change purposes).
Applied standards
5.
This unit corresponds to the Council Directive 93/42/EEC from
14 June 1993 about medical products and bears the sign CE 0123
(TÜV SÜD Product Service GmbH)
•
Meets the requirements ASTM E-1966
•
Metrological control
4.
EN 12470:2003 Medical thermometers part 5: Requirements to infrared ear
thermometers
•
IEC 60601-1:2005 ·Medical electrical devices part 1:
General determination for safety including essential performance features
•
IEC 60601-1-2 : 2001 + A1:2004 ·Medical electrical devices - part 1-2:
General determination for safety - Collateral standard: Electromagnetic
compatibility - Requirements and tests
•
ANL_DT_Ear_D-xaktuell_05_EN.indd44-45 44-45