background image

UDT INSTRUMENTS RMA FORM 

8581 Aero Drive  

  San Diego, CA 92123  

 

  

Phone (858) 279-8035 Fax (858) 576-9286

 

http://www.udtinstruments.com

RMA REQUEST DATE _____________     RMA NUMBER _____________ 

(assigned by UDT)*

 

Please check appropriate box:

 CALIBRATION  

 

   REPAIR 

 

 

 

 WARRANTY 

 

 

 

BILL TO: 

SHIP TO: 

ATTN: ATTN: 

Street Address 

Street Address 

City, State, Zip 

City, State, Zip 

E-Mail Address 

Preferred  Payment:   

 

 Visa   

 

 

Master Card 

Credit Card # 

PHONE NUMBER 

    -          - 

FAX NUMBER 

            -          - 

NAME ON CREDIT CARD/EXP DATE 

PO # 

Please provide your shipping carrier, preferred method of shipment and shipping carrier account # 

 

 

 

FEDEX

     

 

 UPS

     

 

 DHL

     

 

 

Other

 __________________     Shipping Carrier Account # _________________   

 

 

 

Method of Shipment (eg. Overnight, Next Day, 2

nd

 Day, 3

rd

 Day, Red, Blue, Orange, Ground) 

__________________

 

 

  QTY 

INSTRUMENT DESCRIPTION 

INST. SERIAL # 

SENSOR DESCRIPTION 

SENSOR SERIAL # 

 

 

 

 

 

Electrical Calibration of all meters (REQUIRED)…..    $100.00 

DETAILED CALIBRATION INSTRUCTIONS 

 

  QTY 

INSTRUMENT DESCRIPTION 

INST. SERIAL # 

SENSOR DESCRIPTION 

SENSOR SERIAL # 

 

 

 

 

 

Electrical Calibration all meters (REQUIRED)…..    $100.00 

DETAILED CALIBRATION INSTRUCTIONS 

 

TOTAL ESTIMATE: ________________ US Dollars 

If the unit is in need of repair, an evaluation fee of $1

75

.00 will apply.  If the cost of the repair ex- 

ceeds the evaluation fee, the customer will be notified for approval BEFORE any work is performed. 

 

_____________________________              ____________________________      _______________ 

Tonda Arbaugh 

 

 

 

 

         Customer Approval                         Date 

[email protected]  

 

We would PREFER to use your shipping carrier when sending back your unit(s). 

Otherwise, all orders will be shipped UPS Ground Pre-Paid and this fee will be 

added to the invoice unless specified otherwise in the shipping carrier box above.

 

*RMA Numbers (upon issue from UDT Instruments) are valid for 60 calendar days! 

Last updated 

October 2007

 

Содержание 301DIV

Страница 1: ... underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective ...

Страница 2: ...Model 301DIV SIGNAL CONDITIONING AMPLIFIER Revision B July 20 2005 UDT Instruments 8581 Aero Drive San Diego CA 92123 Phone 858 279 8035 Fax 858 576 9286 ...

Страница 3: ...ccidentally blown If the PTC device has either shut down your equipment or has increased resistance to the point where it affects unit performance simply turn off the equipment and allow the PTC device to cool for about 15 to 20 seconds The 301 DIV may then be turned back on Please note that the most common way in which current is increased to an unsafe level is by improperly biasing the detector ...

Страница 4: ...normalized to 10V maximum user adjustable The standard Model 301DIV has a frequency range of DC to 5 kHz A 30 kHz version is also available for high speed applications COMPLETE DETECTOR CABLE ASSEMBLIES For ease of installation and accuracy of measurement UDT offers detector cable assemblies which ensure proper interconnection between photodetector and amplifier pins UDT photodetectors are selecte...

Страница 5: ...n the ZERO potentiometer to electrical zero select two 100 K ohm to 1 Meg ohm resistors matched within 0 15 and connect one resistor between each amplifier input pin E and D and common H Then adjust the zero potentiometer for OV at the position output connector DETECTOR CONNECTION INSTRUCTIONS If UDT detector cable assemblies are employed connect the cable output connector to the 301DIV input If c...

Страница 6: ...Figure 1 Input Connector Orientation Figure 2 Figure 3 Detector Orientation UDT Instruments 8581 Aero Drive San Diego CA 92123 Phone 858 279 8035 Fax 858 576 9286 ...

Страница 7: ...conductive 30 kHz version 100 ohm Detector polarity Selectable common anode LSC and Range Indicators HI LO signal level LEDs aid in SC series or common cathode setting range switch to proper SPOT series value Output voltage Output Adjustments Sum GAIN x ID IE CAL Adjustable scale factor for Position ID IE X 10 V position output ID IE ZERO Provides 2 5 V zero offset Output Voltage Range Sum 0 to 10...

Страница 8: ... 5D Detector Cable Assembly with 35 mm lens adaptor 1239 PIN LSC 30D Detector Cable Assembly with 35 mm lens adaptor 1240 PIN SPOT SC 9D Detector Cable Assembly 1241 PIN SC 4D Detector Cable Assembly 1242 PIN SPOT 2D Detector Cable Assembly PIN LSC 4 Detector only Website www udtinstruments com Rev B July 20 2005 UDT Instruments 8581 Aero Drive San Diego CA 92123 Phone 858 279 8035 Fax 858 576 928...

Страница 9: ...uce the lifetime of the instrument drastically 4 Units with ieee 488 capability must use a shielded cable similar to Hewlett Packard part number HP10833x or Io Tech part number CA 7 X to maintain compliance 5 All coaxial cables must be less than 3 meters long 6 All battery operated units have batteries that are not replaceable by the customer and can only be charged with the battery charger suppli...

Страница 10: ...ducts or can prevent product damage Upon misuse verification that warranty service is required the Sales Department will issue a Return Material Authorization number The item returned shall only be accepted when RMA number The RMA number must appear on the accompanied by a written statement setting forth the nature and outside of the shipping container for proper receipt suspected cause of the all...

Страница 11: ...ESCRIPTION SENSOR SERIAL Electrical Calibration of all meters REQUIRED 100 00 DETAILED CALIBRATION INSTRUCTIONS QTY INSTRUMENT DESCRIPTION INST SERIAL SENSOR DESCRIPTION SENSOR SERIAL Electrical Calibration all meters REQUIRED 100 00 DETAILED CALIBRATION INSTRUCTIONS TOTAL ESTIMATE ________________ US Dollars If the unit is in need of repair an evaluation fee of 175 00 will apply If the cost of th...

Страница 12: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Отзывы: