IPU-100P
4.2 SIP CONFIGURATION (SIP).
The configuration page allows you to configure SIP parameters to ensure the connection to the installation server IPU-360 (SIP server).
The parameters configured here must be consistent with SIP server parameters of the system.
Enable SIP changes
UDE PA system
SIP Server IPAddress (format: XXX.XXX.XXX.XXX):
168.168.0.254
In case the checkbox is checked, the SIP parameters are available to be configured. If not the configuration parameters are blocked.
The signaling communication with the server is SIP. Furthermore due to the public address characteristics, the codifiers and
decoders requires additional information inside the standardized datagram. Choose ON to use the UDE PAsignaling information.
In case of priority or IPU-100P installations, the box must stay in ON option. In case of 100% SIP standard compliance OFF option.
Defines the IP address where the SIP server host. It is required that the address contains the 12 numbers along with the 3
breakpoints.
Example:
SIP Server IP:
¡Attention!
It is MANDATORY for the correct operation of the IP AUDIO devices of UNION DESARROLLOS ELECTRONICOS
that the SIP Server IP address is FIXED address (static type).
The configuration parameters are:
IPU-100P
User Manual - IPU-100P
28
9
610.462A
Rev. 0
4.- DEVICE CONFIGURATION (WEBSERVER)