background image

IPU-100P

BEEPER function:

Output Bass (Gain):

Example:

+0dB (mín.)

+15dB (max.)

Output Bass (Cut-off Frequency):

Example:

20Hz (mín.)

150Hz (max.)

Output Treble (Gain):

Example:

-12dB (max atenuation)

+0dB (default)

+10.5dB (max gain)

Output Treble (Cut-off Frequency):

Example:

1kHz (mín.)

8kHz (Máx.)

DESK.MIC IN Volume (format: XXX):

Example:

070 (min.)

090

127 (Max.)

EXT.MIC IN Volume (format: XXX):

Example:

010(min.)

090

128 (Max.)

TM OUT Activation Mode:

Activate the acoustic buzzer.
OFF (as Factory Default).
ON

Filter can be used to supplement the low frequency response, from +0dB (default set) to +15dB.

Filter cut-off frequency for supplement low frequency response.

Filter can be used to attenuate/supplement the high frequency response, from -12dB to +10.5dB.

Filter cut-off frequency for attenuate/supplement high frequency response.

Select between 070 and 127, the gain level to be applied to audio from the desk control IPU-100P connected to the IPU-100. This
configuration parameter can only be used in IPU-100P modeAlways use a 3-digit format.

Select between 010 and 128, the gain level to be applied to audio from the external microphone of the desk control (IPU-100P) connected
to the IPU-100 (CM-23 is the recommended microphone). This configuration parameter can only be used in IPU-100P mode. Always use
a 3-digit format.

There are few input calls (depending on the extension) that allow the activation of this mode:
- OFF.
-Any incoming call:Any incoming call with the server specifications will activate the TM OUT.
- Only voice calls: Only incoming calls from desk control (IPU-100P), will activate the TM OUT.

SERVER SPECIFICATIONS

2500

2999

4000

4999

Codifier extension between

and

, activate the TM OUT in the decoder.

All extensions between

and

will activate the decoder TM OUT

User Manual - IPU-100P

21

610.462A

Rev. 0

4.- DEVICE CONFIGURATION (WEBSERVER)

28

Содержание IPU-100P

Страница 1: ...1 Erasing Editing 4 3 2 P A Zones edit page User Manual IPU 100P 28 1 610 462A Rev 0 MESSAGE SPEECH USB FAULT ON IPU 100P IPU 100P Paging Desk Zona 1 Zona 6 Zona 2 Zona 7 Zona 3 Zona 8 Zona 4 Zona 9 Zona 5 Zona 10 1 00 00 1001 1006 1002 1007 1003 1008 1004 1009 1005 1010 PAGING DESK Audio over IP Madrid Barcelona Tel 34 93 477 28 54 Fax 34 93 261 17 52 ude udeaudio com Avda BARCELONA 24 08970 SANT...

Страница 2: ...ity systems allowing interconnecting with IP devices following SIP standard Unión Desarrollos Electrónicos also offers theIPU 360SIPserverthatwillcentralizeandcoordinateallcommunicationofIPpagingelementsensuringmaximumfunctionality ofallofthem withminimalrisk The IPU 100P paging desk allow the user to manage the IP PA system calling individual or groups of zones with user friendly graphicinterface...

Страница 3: ...iple configurations and connections adding flexibility to combine the wide range of amplifiers preamps poweramps ofUNIÓNDESARROLLOSELECTRÓNICOS 2 TYPICAL APPLICATION OF IPU 100P IPU 100P Cable UTP Cable UTP Protocolo RS 485 AUDIO Protocolo IP IPU 100 IPU 1025 IPU 100P OUT IN OK DEVICE CALL FAULT CONFIG NET ACTIVITY USB ON IP MESSAGE SPEECH USB FAULT ON IPU 100P IPU 1025 IPU 100 IPU 100 IPU 1025 IP...

Страница 4: ...l microphone LED FAIL DEVICE This indicator is activated when there is a connection problem with IPU 100 or IPU 1025 LED LINK FAIL This indicator is activated when exist a wrong data transmission with IPU 100 or IPU 1025 LED ON This indicator shows the equipment is properly powered and main application is running USB CONNECTOR The USB connector allows the firmware update CONTROLS CONNECTORS AND IN...

Страница 5: ...connect handheld microphones with push to talk switch Unión Desarrollos Electrónicos recommends tousetheCM 23microphone 5 4 2 1 1 5 4 2 3 3 XLR I O This connector allows connection of an IPU 100P or allows the expansion and control of external devices through the digital bus also has a balanced analog audio input and one output that allow the exchange of audio between the IP Paging Desk and the IP...

Страница 6: ... 100P EXTENSIONSIPCONFIGURATION ONLYIPU 100Pmode The public address zone configuration with an IPU 100P desk control must be done with a IPU 100 codifier It is not possible to make the desk control configuration with the touch screen The extension web server of the IPU 100 menu will allow erasing all IPU 100P zone buttonsoreditingthePAbuttonsoftheIPU 100Pdeskcontrol User Manual IPU 100P 6 610 462A...

Страница 7: ...ich is why we may appear different from pictures provided in this document and results that you can get the productyouhavepurchased IfyouhaveanydoubtsconsultthetechnicaldepartmentofUDE 1 2 2 4 1 5 3 IPU 100P 4 DEVICECONFIGURATION WEBSERVER The IPU 100 configuration is done by accessing to the IP address assigned to the device by the site administrator if you work in Manualmodeassignment Static Mod...

Страница 8: ...inputs and outputs StatusMonitor LEDsstatus Activationsignalstatus Sensorlevelstatus Inthisareayoucanseethreezones Itshowsinrealtimethestatus on off flashing ofallindicatorspresentonthefrontpanel Showsthestateoftheactivationsignalsofdifferentbasicfunctionssuchas VOXactivated MICactivated etc It shows the voltage measurement of the sensors included on the device 24V Adaptor 24V Backup Battery VOX s...

Страница 9: ...e due to the public address characteristics the codifiers and decodersrequiresadditionalinformationinsidethestandardizeddatagram ChooseONtousetheUDEPAsignalinginformation IncaseofpriorityorIPU 100Pinstallations theboxmuststayinONoption Incaseof100 SIPstandardcomplianceOFFoption Defines the IP address where the SIP server host It is required that the address contains the 12 numbers along with the 3...

Страница 10: ...cate with the IPU 360 SIP server The standard default value in the device is 05060 you should keep to ensure compatibility with different SIP servers Remember to always use a configuration with 5 digits Local Port Defines the data transmission UDP port Voice INFO used by the IPU 360 SIP server to communicate with the IPU 100 The standard default value is 00000 automatic mode you should keep this v...

Страница 11: ...mation of the max number of priorities consulttheIPU 360datasheet The must be configured with audio sources like MP3 players or Microphones like PZ 40 for Music on holdcalls Itisadifferentpriorityfromthe thatonlyconcernsdeskcontrolmicrophones These characteristics give tools to program de PAsystem over IP if the IPU 100 is linked with an IPU 100P desk control a priority desk can be applied This pr...

Страница 12: ...on label Description label To edit the IPU 100P zones exists 2 ways 1 Erasing the whole desk control memory 2 Editing zones keeping the zones configuration The main page have 10 PA buttons and navigation icons Each button zone can be edited with a description text and numbers of zones to call decoders The maximum number of PA zones will be a totally broadcast message for all the zones configured i...

Страница 13: ...econds to 44 minutes to erase all data The IPU 100P screen while the erase process is execute will keep out of work for any paging call Also a deleting data message will be printedtogiveuserinformation Zoneeditpage When the erase process has finished the webpagewill beredirected tothezone edit webpage also thetouch screen oftheIPU 100Pwill work Caution The erasing process is irreversible in case o...

Страница 14: ...nepage clickon iconintheleftmenuandclick If you did the erase memory process you will be redirected to the PA zones edit page of the IPU 100P The zone edit page has two main areas one is the general navigation and edition of the buttons that already exist in the desk control IPU 100P andanother areaallowseditingonespecificbutton addingthelabelandthedifferentextensionsthatwillcall User Manual IPU 1...

Страница 15: ... extension 1300 typing 300 and clicking the new number appears in the extension Validate Senddata Whenallextensions labelsandbuttonsareready clickon Thisactionmustbedoneeverytimeonebuttonisedited Extensionconfiguration To enter the extensions in a button the configuration must be done one by one extension that is enter one extension send the informationandsuccessivelyforalltheextensiontobeinonebut...

Страница 16: ...ame Extensiontocall BOTTON3 Yard 1003 1004 1010 Buttonname Extensiontocall Zone 1 1001 Main room 002 Yard IPU 100P Paging Desk Zone 1 1 00 00 1001 Main room 002 Yard 003 003 ZONE EDIT PAGE Without any data inside the system the webpage should look like Edition of button 1 First extension to configure inside the button 1 User Manual IPU 100P 16 610 462A Rev 0 4 DEVICE CONFIGURATION WEBSERVER 28 ...

Страница 17: ...1 appears in the extension box In button number one has only one extension to call 1001 there is no other extension to configure and configuration must be uploaded Click on button BOTTON 1 EDITION Button 1 configuration has been saved and screen shows the new button IPU 100P Paging Desk Zona 1 1 00 00 1001 4 5 3 2 1 001 1001 User Manual IPU 100P 17 610 462A Rev 0 4 DEVICE CONFIGURATION WEBSERVER 2...

Страница 18: ... 1002 Confirm extension with Extension 1002 appears in the extension box Type the second extension to call in button 2 this is extension 400 equal to 1400 Confirm extension with Extension 1400 appears in the extension box In button number two has only two extensions to call 1002 1400 there is no other extension to configure and configuration must be uploaded Click on button BOTTON 2 EDITION 4 4B 5...

Страница 19: ...second extension to call in button 3 this is extension 004 equal to 1004 Confirm extension with Extension 1004 appears in the extension box Type the second extension to call in button 3 this is extension 010 equal to 1010 Confirm extension with Extension 1010 appears in the extension box In button number three has three extensions to call 1003 1004 and 1010 there is no other extension to configure...

Страница 20: ...rm a reboot of the device VoIP Codec G 711 u Law G 711 a Law G 722 ADPCM PCM Allows selection of the codec to be used to encode both outgoing and incoming calls when the audio source is a microphone The options are as follows 8 bits logarithmic compression and 8KHz sampling frequency Quality Low As Factory Default 8 bits logarithmic compression and 8KHz sampling frequency Quality Low 8 bits Adapti...

Страница 21: ...nd 127 the gain level to be applied to audio from the desk control IPU 100P connected to the IPU 100 This configurationparametercanonlybeusedinIPU 100PmodeAlwaysusea3 digitformat Select between 010 and 128 the gain level to be applied to audio from the external microphone of the desk control IPU 100P connected to the IPU 100 CM 23 is the recommended microphone This configuration parameter can only...

Страница 22: ...TECONFIGURATION Date SaveDATE Entertheday monthandyeardesired consideringalwaysuse2digitsformat Clickon toupdatethesystemcalendar Alwaysusetheformat dd mm yy Example Day dd 20 Month mm 01 Year yy 13 Alwaysusetheformat hh mm ss Example Hour hh 22 Minute mm 45 Seconds ss 55 User Manual IPU 100P 22 610 462A Rev 0 4 DEVICE CONFIGURATION WEBSERVER 28 ...

Страница 23: ...OOT The IPU 100 can be remote rebooted just click to the icon on the left menu and confirm clicking on icon 28 23 Rev 0 IPU 100 IPU 100 IPU 100 IPU 100 Caution The erasing process is irreversible in case of error the memory information cannot be recovered 4 DEVICE CONFIGURATION WEBSERVER 610 439A Installation Configuration Use IPU 100 ...

Страница 24: ...trol is managing the information and synchronizingwiththeIPU 100orIPU 1025tobeconnectedtothenet Themainscreenhavedifferentareas IPU 100P Paging Desk Initializating IPU 100P Please Wait IPU 100P Paging Desk Zona 1 Zona 2 Zona 3 Zona 4 1 08 15 1001 1002 1003 1004 5 INITIALIZE PROCESS User Manual IPU 100P 28 24 610 462A Rev 0 ...

Страница 25: ...4 0004 Example For an installation with 7 PA zones the touch screen will show only 7 buttons 5 2 PA BUTTONS DISPLAY Buttons without any zone s Navigation button will be disabled because exist less than 10 zones Navigation button Example Foraninstallationof23zones willexist3pagesof10 10 3buttons In page number 1 there are the 10 first buttons page 2 page 3 In page number 2 there are 10 buttons more...

Страница 26: ...AINSCRENDESCRIPTION Themainscreenhavedifferentareas A1 A2 A3 A4 IPU 100P Paging Desk Zone 1 Zone 6 Zone 2 Zone 7 Zone 3 Zone 8 Zone 4 Zone 9 Zone5 Zone 10 1 00 00 1001 1006 1002 1007 1003 1008 1004 1009 1005 1010 A2 A3 A4 A1 Index number The number depend on the user navigation on the total PA zone buttons programmed the user can use it to know which range of PA zone buttons is on the screen Next ...

Страница 27: ...g Desk Zona 1 Zona 6 Zona 2 Zona 7 Zona 3 Zona 8 Zona 4 Zona 9 Zona 5 Zona 10 1 00 00 1001 1006 1002 1007 1003 1008 1004 1009 1005 1010 IPU 100P Paging Desk Zona 1 Zona 6 Zona 2 Zona 7 Zona 3 Zona 8 Zona 4 Zona 9 Zona 5 Zona 10 1 00 00 1001 1006 1002 1007 1003 1008 1004 1009 1005 1010 IPU 100P Paging Desk Zona 1 Zona 6 Zona 2 Zona 7 Zona 3 Zona 8 Zona 4 Zona 9 Zona 5 Zona 10 1 00 00 1001 1006 1002...

Страница 28: ... Colour will change to blue Tap the Zone 4 button 1004 Colour will change to blue 3 IPU 100P Paging Desk Zona 1 Zona 6 Zona 2 Zona 7 Zona 3 Zona 8 Zona 4 Zona 9 Zona 5 Zona 10 1 00 00 0001 0006 0002 0007 0003 0008 0004 0009 0005 0010 Iftheoperator wants tosend another message only totheZone 1 2 and4 Justpressthe again the IPU 100P keeps in memory the last zone selection PTTbutton The operator can ...

Отзывы: