Technician
Operations
Page 65 | August 17, 2010
Note:
If the Enabled button is already displayed, touch
Enabled
to choose to have your test
alarms NOT sent to central monitoring.
IMPORTANT:
If you enable
Send Test Alarm Messages
, contact your central monitoring station
and tell them you are testing your system.
4.
Ensure all the security zones are unfaulted (that is, doors and windows closed, motion detectors
not showing motion, etc).
The Alarm Test Checklist is displayed.
5.
Ensure all the security zones are unfaulted (that is, doors and windows closed, motion detectors
not showing motion, etc.).
When the security zones are ready for testing, “Ready to Arm” is displayed under the Arm button.
6.
Touch
Arm
.
Your security system is armed in the special Test mode. The Exit Delay is only 10 seconds long. Motion sensors are
turned off (not tripping alarms but recording events) until an Entry/Exit security zone is faulted.
The Arm button changes to a
System Armed
notice.