PAGE 2
3330 Earhart Drive, Suite 208
|
Carrollton, TX 75006
|
Office: 972.556.0916
|
Fax: 972.910.8384
OPM1
EXAMPLE 1:
SINGLEMODE FIBER, POINT-TO-POINT, 1 JUMPER
Fiber Type
Connectors Used
Test Jumper Setup
OPM Used
OLS Used
Singlemode
LC
Simplex jumper SC/LC
OPM1
LSSM
Page 3
M-UM038-01 RP 460 Reference and Test
DMT
Example 1: Singlemode Fiber, Point-to-Point, 1 Jumper
Fiber Type
Singlemode
Connectors Used
LC
Test Jumper Setup
Single
OPM Used
RP 460
OLS Used
DLS 355
Fiber-Under-Test
The fiber-under-test is singlemode with LC
connectors on each end. The fiber-under-test may
be up to 250 kilometers long. In this example, the
fiber-under-test is 400 meters long.
Test Jumper
The test jumper is a one-meter singlemode fiber
with SC and LC connectors. The SC connector will
be plugged into the DLS 355 laser source and the
LC connector will be used to interface with the
fiber-under-test.
Power Meter
The RP 460 power meter is set to the
1550nm wavelength. The 1310nm
wavelength may also be used. Always
match the wavelength on the RP 460
to the wavelength on the DLS 355. The
adapter on the RP 460 is the AC 029 LC
adapter.
Light Source
The DLS 355 laser source is set to the
1550nm wavelength. The 1310nm
wavelength may also be used. The
adapter is the default AC 022B SC adapter.
400m Fiber
1m Jumper
Page 3
M-UM038-01 RP 460 Reference and Test
DMT
Example 1: Singlemode Fiber, Point-to-Point, 1 Jumper
Fiber Type
Singlemode
Connectors Used
LC
Test Jumper Setup
Single
OPM Used
RP 460
OLS Used
DLS 355
Fiber-Under-Test
The fiber-under-test is singlemode with LC
connectors on each end. The fiber-under-test may
be up to 250 kilometers long. In this example, the
fiber-under-test is 400 meters long.
Test Jumper
The test jumper is a one-meter singlemode fiber
with SC and LC connectors. The SC connector will
be plugged into the DLS 355 laser source and the
LC connector will be used to interface with the
fiber-under-test.
Power Meter
The RP 460 power meter is set to the
1550nm wavelength. The 1310nm
wavelength may also be used. Always
match the wavelength on the RP 460
to the wavelength on the DLS 355. The
adapter on the RP 460 is the AC 029 LC
adapter.
Light Source
The DLS 355 laser source is set to the
1550nm wavelength. The 1310nm
wavelength may also be used. The
adapter is the default AC 022B SC adapter.
400m Fiber
1m Jumper
The fiber-under-test is singlemode with LC connectors
on each end. The fiber-under-test may be up to 250
kilometers long. In this example, the fiber-under-test is
400 meters long.
TEST JUMPER
The test jumper is a one-meter singlemode fiber with SC
and LC connectors. The SC connector will be plugged
into the LSSM laser source and the LC connector will be
used to interface with the fiber-under-test.
POWER METER
The OPM1 power meter is set to the 1550nm
wavelength. The 1310nm wavelength may also
be used. Always match the wavelength on the OPM1
to the wavelength on the LSSM. The adapter on the
OPM1 is the OPAL LC adapter.
LIGHT SOURCE
The LSSM laser source is set to the 1550nm
wavelength. The 1310nm wavelength may also be
used. The adapter is the default OPAS SC adapter.
FIBER-UNDER-TEST
400m Fiber
1m Jumper
Содержание TEK-3
Страница 2: ...SECTION ONE LSMM LED LIGHT SOURCE QUICK START GUIDE NORTH AMERICA ...