![Ublox TOBY-L2 series Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/ublox/toby-l2-series/toby-l2-series_system-integration-manual_3394985050.webp)
TOBY-L2 and MPCI-L2 series - System Integration Manual
UBX-13004618 - R28
System description
Page 50 of 164
AT+UPSV HW flow control
RTS line
DTR line
Communication during idle-mode and wake up
0
Enabled (AT&K3) ON
ON or OFF Data sent by the DTE is correctly received by the module.
Data sent by the module is correctly received by the DTE.
0
Enabled (AT&K3) OFF
ON or OFF Data sent by the DTE is correctly received by the module.
Data sent by the module is buffered by the module and will be correctly
received by the DTE when it is ready to receive data (i.e. RTS line will be ON)
0
Disabled (AT&K0) ON or OFF ON or OFF Data sent by the DTE is correctly received by the module.
Data sent by the module is correctly received by the DTE if it is ready to
receive data, otherwise the data is lost.
1
Enabled (AT&K3) ON
ON or OFF Data sent by the DTE is buffered by the DTE and will be correctly received by
the module when it is ready to receive data (when the UART is enabled).
Data sent by the module is correctly received by the DTE.
1
Enabled (AT&K3) OFF
ON or OFF Data sent by the DTE is buffered by the DTE and will be correctly received by
the module when it is ready to receive data (when the UART is enabled).
Data sent by the module is buffered by the module and will be correctly
received by the DTE when it is ready to receive data (i.e. RTS line will be ON).
1
Disabled (AT&K0) ON or OFF ON or OFF The first character sent by the DTE is lost by the module, but after ~5 ms the
UART and the module are woken up: recognition of subsequent characters is
guaranteed only after the UART / module complete wake-up (i.e. after ~5 ms).
Data sent by the module is correctly received by the DTE if it is ready to
receive data, otherwise the data is lost.
2
Enabled (AT&K3) ON or OFF ON or OFF Not Applicable: HW flow control cannot be enabled with AT+UPSV=2.
2
Disabled (AT&K0) ON
ON or OFF Data sent by the DTE is correctly received by the module.
Data sent by the module is correctly received by the DTE if it is ready to
receive data, otherwise data is lost.
2
Disabled (AT&K0) OFF
ON or OFF Data sent by the DTE is lost by the module
14
.
Data sent by the module is correctly received by the DTE if it is ready to
receive data, otherwise data is lost.
3
Enabled (AT&K3) ON
ON
Data sent by the DTE is correctly received by the module.
Data sent by the module is correctly received by the DTE.
3
Enabled (AT&K3) ON
OFF
Data sent by the DTE is buffered by the DTE and will be correctly received by
the module when it is ready to receive data (when the UART is enabled).
Data sent by the module is correctly received by the DTE.
3
Enabled (AT&K3) OFF
ON
Data sent by the DTE is correctly received by the module.
Data sent by the module is buffered by the module and will be correctly
received by the DTE when it is ready to receive data (i.e. RTS line will be ON).
3
Enabled (AT&K3) OFF
OFF
Data sent by the DTE is buffered by the DTE and will be correctly received by
the module when it is ready to receive data (when the UART is enabled). Data
sent by the module is buffered by the module and will be correctly received by
the DTE when it is ready to receive data (i.e. RTS line will be ON).
3
Disabled (AT&K0) ON or OFF ON
Data sent by the DTE is correctly received by the module.
Data sent by the module is correctly received by the DTE if it is ready to
receive data, otherwise data is lost.
3
Disabled (AT&K0) ON or OFF OFF
Data sent by the DTE is lost by the module
15
.
Data sent by the module is correctly received by the DTE if it is ready to
receive data, otherwise data is lost.
Table 12: UART and power-saving summary
14
Only the first character sent by the DTE is lost by ‘01’, ‘60’ TOBY-L201-02S product versions: the UART and the module are
woken up after ~5 ms due to wake up via data reception, and recognition of subsequent characters is guaranteed after the
UART / module wake-up.
15
Only the first character sent by the DTE is lost by ‘01’, ‘60’ TOBY-L201-02S product versions: the UART and the module are
woken up after ~5 ms due to wake up via data reception, and recognition of subsequent characters is guaranteed after the
UART / module wake-up