background image

WWDZWx User Manual

Date:9-Jun-2021

Ubitech Ltd.

Version:0.3

8

7

HOW 3-Axial ACTION SENSOR WORKS

7.1 3-Axial Action Sensor – Gesture Recognition Procedure

-

End-user can use built-in 3-Axial Accelerometer to replace physical touchable key, Custos WWD can perform below actions
after it woke up by shaking it. (*Please note that 3-Axial Action Sensor only activated while WWD included into Z-Wave
Network.)

i.

Send out Notification CC packet to Gateway, (Refer to item 13.1.1)

ii.

Perform Exclusion Gesture, (Refer to item 12.3)

iii.

Perform Factory Default Reset Gesture, (Refer to item 12.4)

-

Custos WWD only supports below movement as wake up WWD from sleep mode, shake it vertically or horizontally as below,

Shaking in Vertical

Shaking in Horizontal

Содержание Custos WWDZWU

Страница 1: ...WWDZWx User Manual Date 9 Jun 2021 Ubitech Ltd Version 0 3 Custos Wireless Water Detector Technology for Humanity...

Страница 2: ...2 3 Software Specifications 3 3 WHAT S INSIDE IN THE BOX 4 3 1 Custos WWD Main Unit x 1 Figure 3A 4 3 2 Remote Water Detection Probe x 1 Optional Figure 3B 4 4 UNDERSTANDING CUSTOS WWD 5 4 1 Connecto...

Страница 3: ...y Default Reset Mode Only works in Mesh Network Mode 10 9 4 Water Leak Sensor Alarm 10 10 PHYSICAL INSTALLATION 11 10 1 Connect the Remote Sensor Probe Optional 11 11 USER INTERFACE BEHAVIORS 12 11 1...

Страница 4: ...cturer Specific 19 16 4 Notification CC 20 16 5 Indicator CC 20 16 6 Basic CC Mapping of Water WWD 20 16 7 Wake Up CC 20 16 8 Association Group Info AGI 21 16 9 Supported Command Classes In NIF 22 16...

Страница 5: ...orm factor detects water from either in body detection probe on 4 sides as well as optional remote wired water detection probe It is a perfect companion for Custos BVS to work in concerto as a complet...

Страница 6: ...2 F 10 50 C Relative Humidity 8 80 2 2 Hardware Characteristic Parameter Value Z Wave Module ZGM130S037HGN1 Z Wave RF Distance 40m Indoor 120m Outdoor Region Frequency US 908 4 916MHz FCC CFR47 Part 1...

Страница 7: ...n Generic Device Type 0x07 GENERIC_TYPE_SENSOR_NOTIFICATION Specific Device Type 0x01 SPECIFIC_TYPE_NOTIFICATION_SENSOR Security Class Non Security S2 Unauthenticated and S2 Authenticated SmartStart S...

Страница 8: ...ech Ltd Version 0 3 4 3 WHAT S INSIDE IN THE BOX Standard Custos Wireless Water Detector WWD package comes with below items 3 1 Custos WWD Main Unit x 1 Figure 3A 3 2 Remote Water Detection Probe x 1...

Страница 9: ...ure Sensor Built in Temperature Sensor k Battery Cover e Leak Sensor 1 Built in Water Detection Probe l Battery Contact Connect main unit Battery Cover f Leak Sensor 2 Socket for Remote Water Detectio...

Страница 10: ...ype Lithium 1200mAh 5 2 How to change battery Remove the screws of battery cover Figure 5A Replace new ER14250 battery Make sure the Gasket is installed between the cover body for waterproof Figure 5B...

Страница 11: ...eter Sensor for gesture recognition by detecting a series of movements Once the 3 Axial Action Sensor is activated you also can see below Visual and Sound Indicators response with the 3 Axial Action S...

Страница 12: ...ctions after it woke up by shaking it Please note that 3 Axial Action Sensor only activated while WWD included into Z Wave Network i Send out Notification CC packet to Gateway Refer to item 13 1 1 ii...

Страница 13: ...t to create effective detection by probes from both end To achieve better result please put the WWD on the floor flatly 8 3 Remote Water Detection Probe To make sure Sensor Probe works properly show a...

Страница 14: ...Leak Detection Temperature Report SmartStart Classic Inclusion Exclusion Factory Default Reset Custos WWD also can associate with Custos BVS to shut off the Water Valve when detected Water Leak 9 3 F...

Страница 15: ...e Remote Sensor Probe Optional i Remove Dust Cover Please do not remove Dust Cover if Remote Sensor Probe not installed Figure 10A ii Insert the 3 5mm jack of Socket for Remote Water Detection Probe t...

Страница 16: ...ill stop to execute next step Timeout n a Red flash x2 2 times Event timeout and will stop to execute next step Waked up Standalone After triggered by 3 Axial sensor Yellow ON x1 1 time Waked up and 3...

Страница 17: ...ity 2 Command Class while a Security S2 enabled controller is needed It supports SmartStart and Classic Inclusion For adding Custos WWD into Z Wave Network end user can use SmartStart for Inclusion 12...

Страница 18: ...N LED ON iii Then stop shaking it leave WWD on the table in Horizontal position as Figure 12A iv Wait for Position Recognition confirmation UI with Buzzer Sounds GREEN LED flashing 2 times Event succe...

Страница 19: ...figuration settings to the default To perform Factory Default Reset as following steps Only works in Mesh Network Mode i Shaking Custos WWD in Vertical Horizontal to wake up it until get 1x Buzzer Sou...

Страница 20: ...g steps i Shaking Custos WWD in Vertical Horizontal to wake up it until get 1x Buzzer Sound 1x GREEN LED ON ii Then stop shaking WWD then wait for timeout in 10 seconds iii After time out then WWD wil...

Страница 21: ...ation CC Built in Water Leak Alarm Sends to Association Group 2 Remote Water Leak Alarm Sends to Association Group 3 14 2 Water Leak Alarm Cancellation Water Leak Alarm Cancellation action sets Basic...

Страница 22: ...rt to Gateway if the temperature is changed every 1 C or 4 F Refer to item 16 10 0x31 Temperature Level Change to auto report The Heat Alarm Overheat and Underheat also will send to Gateway at wake up...

Страница 23: ..._ALARM User Icon Type 0x0C05 ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_WATER_ALARM 16 2 Version CC 16 3 Manufacturer Specific Parameter Value Z Wave Protocol Library Type 0x03 Z Wave Protocol Version 0x0...

Страница 24: ...vent Power Management 0x08 State idle 0x00 Notification value for the state variable going to idle V5 Battery fluid is low 0x11 16 5 Indicator CC Parameter Value Indicator ID 0x50 Node Identify Proper...

Страница 25: ...0x02 Water leak detected no location support Power Management Notification 0x08 0x00 State Idle 0x11 Battery Fluid is low 2 Built in Leak Sensor Probe 5 Basic Set 0x00 IDEL CANCEL Based on Configurat...

Страница 26: ...upport Support TRANSPORT_SERVICE 2 Support Support Support VERSION 3 Support Support Support MANUFACTURER_SPECIFIC 2 Support Support Support DEVICE_RESET_LOCALLY 1 Support Support Support INDICATOR 3...

Страница 27: ...5 Altering capabilities False Advanced False Description Water Leak Probes Temperature Function Set Disable Enable Default all enabled Value Function Bit 0 Built in Water Detection Probe Default Enabl...

Страница 28: ...evel Report Properties Size 1 Bytes Min Value 0x01 1 Format Unsigned Integer Max Value 0x63 99 Read only False Default Value 0x1E 30 Altering capabilities False Advanced False Description Configure Ba...

Страница 29: ...e 0x0000 0 0 C 0x0100 0 for 0 F Format Unsigned Integer Max Value 0x10FF 255 255 C 0x11FF 4607 255 F Read only False Default Value 0x0000 0 0 C 0x0100 256 for 0 F Altering capabilities False Advanced...

Страница 30: ...in Value 0x0000 0 0 C 0x0100 0 0 F Format Unsigned Integer Max Value 0x00FF 255 255 C 0x01FF 511 255 F Read only False Default Value 0x0000 0 0 C 0x0168 360 104 F Altering capabilities False Advanced...

Страница 31: ...Leak Cancellation Basic SET Properties Size 1 Byte Min Value 0x00 0 Format Enumerated Max Value 0x02 2 Read only False Default Value 0x00 0 Altering capabilities False Advanced False Description Conf...

Страница 32: ...r Value Basic SET Properties Size 1 Byte Min Value 0x00 0 Format Enumerated Max Value 0x02 2 Read only False Default Value 0x00 0 Altering capabilities False Advanced False Description Configure Assoc...

Страница 33: ...nfigure Association Group 5 Basic Set value when Freeze Triggered Value Function 0x01 1 Basic ON 0xFF 0x02 2 Basic OFF 0x00 Parameter No 0x47 71 Name AG5 Freeze Recover Value Info Freeze Recover Value...

Страница 34: ...x03 3 Read only False Default Value 0x03 3 Altering capabilities False Advanced False Description Configure Buzzer Function Disable Enable with device action Default 0x03 0 Disable 1 Enable Value Func...

Страница 35: ...including PIN Code and Full DSK string for SmartStart and they re located as below locations PIN code with QR Code on WWD housing Refer to item 4 1 PIN Code 12345 QR Code with full DSK string printed...

Страница 36: ...nd will stop to execute next step 17 3 System Event Event Action LED Buzzer Sound Remark Power On Okay Power Up Y G x1 1 time System Power On Okay after battery installed Device Mode Shipping Triggeri...

Страница 37: ...ked up and 3 Axial sensor is ready In Mesh Network Mode OTA FW Upgrade Starting OTA upgrade procedure Green flash x2 2 times Being to start OTA firmware upgrade Processing G Y R flashing n a OTA is in...

Страница 38: ...WWDZWx User Manual Date 9 Jun 2021 Ubitech Ltd Version 0 3 Contact us if you have any questions https www facebook com g roups 283898176125297 http www ubitech hk...

Отзывы: