Manual

Содержание H1

Страница 1: ...Heating Control H1 Manual...

Страница 2: ...tructions 2021 ubisys technologies GmbH D s seldorf Germany All rights reserved Reproduction and copies also in extracts only with the consent of ubisys technologies GmbH We assume no liability for er...

Страница 3: ...d switch on again 3 3 Set temperature offset Chapter 4 Schedules 4 1 What are schedules and how do I create change them 4 2 How do I pause a schedule vacation mode 4 3 Delete all schedules Chapter 5 M...

Страница 4: ...4 Heating Control H1 Chapter 1 General...

Страница 5: ...The power supply is provided by two lithium batteries type AA with 1 5 V Energizer L91 Ultimate Lithium or comparable Note If you want to control the H1 via the app of another manufacturer you need a...

Страница 6: ...6 Heating Control H1 Chapter 1 General Design H1 Display Button Mounting ring Rotary dial Battery protection foil 100 mm 55 mm...

Страница 7: ...temperature up to 90 C Threaded connection to radiator valve M30 x 1 5 Setting force 100 N Adjusting stroke 5 5 mm Wireless interface frequency 2 4 GHz Wireless interface protocol Zigbee 3 0 Protecti...

Страница 8: ...8 Heating Control H1 Chapter 2 Commissioning...

Страница 9: ...a list of radiator valve adapters at www ubisys de Note To unmount the H1 please use the Unmount function Chapter 5 6 2 2 Initial commissioning with and without gateway Note If you wish to use the H1...

Страница 10: ...n Basic Configuration Open for new devices 3 The Zigbee network is now open for about 4 minutes and your H1 heating controller can join the network 100 mm 55 mm 4 Remove the battery protection foil fr...

Страница 11: ...in Your heating valve is too long or too short so that the H1 cannot start the calibration process 9 Following the calibration the device performs the network startup and tries to connect to an open...

Страница 12: ...jumps back to the start screen as soon as the H1 is in the Zigbee network The device is recognized as a new component and displayed accordingly 1 0 C 2021 09 30 00 13 After 4 seconds of inactivity th...

Страница 13: ...kstart 2 3 Date and time setting To be able to create schedules for your Heating Control H1 you must first set the current date and time Pro ceed as follows for this Drehrad 1 Press and hold the butto...

Страница 14: ...o numbers day flash Use the rotary knob to select the current day and confirm by pressing the button Note To cancel the process press and hold the button for two seconds 0 C 2021 09 30 00 00 10 The ti...

Страница 15: ...15 Heating Control H1 Chapter 3 Set Room Temperature...

Страница 16: ...mperature Via the rotary dial The desired room temperature can be set manually on the device using the rotary dial Pay attention to the display which shows you the set temperature center and the actua...

Страница 17: ...om where the radiator with the H1 is located 4 To set the desired room temperature touch the actual temperature displayed 21 0 C 5 A slider for setting the target temperature will appear Move the slid...

Страница 18: ...he symbol for Switch off by turning the rotary wheel and press the button to confirm 0 C 9 30 3 A check mark will appear in the upper right corner and your heating will now be switched off and will be...

Страница 19: ...ion option of up to 10 C or 10 C For example If it is 3 C warmer in the room than it is displayed on the H1 or in the ubisys app 3 C must be entered in the corresponding menu on the H1 If it is 3 C co...

Страница 20: ...20 Heating Control H1 Chapter 4 Schedules...

Страница 21: ...s not matter whether this temperature was set before or during see section Manual overwrite the time window So if you e g manually set a target temperature of 18 C before the start of the time window...

Страница 22: ...9 22 0 C 9 17 17 0 C MON 0 6 12 18 24 MON 0 6 12 18 24 MON 0 6 12 18 24 09 00 17 00 17 0 C 2 1 06 00 09 00 22 0 C 3 2 06 00 09 00 22 0 C 3 2 1 1 06 00 09 00 22 0 C 3 2 1 1 Press the button to activate...

Страница 23: ...ing the button you can now choose between the following options in the right column Save and quit Your settings are saved and you do not want to create another time slot You will be redirected to the...

Страница 24: ...created proceed as follows 1x 1x 17 00 17 15 17 C 17 00 22 00 22 C 06 00 09 00 22 C 09 00 09 15 22 C MON SUN 6 9 22 0 C 9 17 17 0 C MON FRI SAT SUN MON TUE WED THU FRI SAT SUN MON 0 6 12 18 24 MON 0...

Страница 25: ...otary dial you can switch to another slot To edit press the button Or use the rotary dial to switch to the following options selected dark background and then also confirm by pressing the button Add s...

Страница 26: ...be saved 17 00 17 15 17 C 17 00 22 00 22 C 06 00 09 00 22 C 09 00 09 15 22 C MON SUN MON FRI SAT SUN MON TUE WED THU FRI SAT SUN 00 00 00 00 7 0 C 1 06 00 09 00 22 0 C 1 09 0 09 1 22 0 2 1 09 00 17 00...

Страница 27: ...e button to activate the display Press the button again to enter the first menu C 2 Select the Vacation mode icon by turning the dial and press the button to confirm C 3 A check mark will also appear...

Страница 28: ...as follows 1x 1x 6 9 22 0 C 9 17 17 0 C MON 0 6 12 18 24 MON 0 6 12 18 24 MON 0 6 12 18 24 22 0 C 22 0 C 22 0 C 1 Press the button to activate the display Press the button again to enter the first men...

Страница 29: ...29 Heating Control H1 Chapter 5 More Functions and Information...

Страница 30: ...air update function i e the device can be supplied with new firmware versions via the gateway using Zigbee radio technology 5 3 Calibrate the H1 The H1 is automatically calibrated during initial comm...

Страница 31: ...ting valve Your heating valve is stuck so that the H1 cannot move it in Your heating valve is too long so that the H1 cannot start the calibration process 5 4 Changing the batteries If the device no l...

Страница 32: ...ding Scenario Heating control H1 is connected to a wall thermostat The H1 is configured as initiator When an attribute e g setpoint temperature is changed at H1 a report with the value is generated an...

Страница 33: ...e symbol flashes 6 Press the button again to confirm 0 C 30 7 The icon for Finding Binding appears with an arrow pointing upwards 8 Press the button again to configure the device as Initiator In this...

Страница 34: ...ing In order to facilitate the disassembly you should allow the ram of the H1 to retract Proceed as follows for this 1 Press and hold the button for 10 seconds to enter the second menu 2 By operating...

Страница 35: ...ndard settings you may reset the device to factory settings This resets the H1 to the factory settings Proceed as follows 1 Press and hold the button for 10 seconds to enter the second menu 2 By opera...

Страница 36: ...ncel now press the button You will then return to the menu mode 00 mm 55 mm 8 Turn the rotary dial to the right If you turn the rotary dial to the left the process will be canceled and you return to t...

Страница 37: ...brate Measurement process for matching the H1 tappet to the radiator valve Calibrate Calibration was completed successfully Calibrate Calibration was not completed successfully Join Zigbee network The...

Страница 38: ...C 30 Radio top left of display Indicates the quality of the Zigbee radio connection Battery top right of display Shows the battery status Battery symbol much filled battery level high Battery symbol...

Страница 39: ...is will be regulated to approx 16 C Vacation mode Vacation mode is active Identify The device identifies itself in order to be able to locate it only appears in combination with an app Open Zigbee net...

Страница 40: ...e assumes the function of an target during the finding bin ding process within the Zigbee network 0 C 2021 09 30 Factory reset The device is to be reset to factory settings Factory reset Security quer...

Страница 41: ...s must be replaced The surface must not be cleaned with sponges and scouring agents This will result in scratches or a dull sur face Only use a damp non fluffy cloth and no abrasives or cleaning agent...

Страница 42: ...ing Control H1 Chapter 5 More Functions and Information 5 11 Contact ubisys technologies GmbH Neumannstr 10 40235 D sseldorf Germany T 49 211 54 21 55 00 F 49 211 54 21 55 99 support ubisys de www ubi...