Product information
13
printed: 03/2012 Subject to change!
<
RTUserManual.doc
3.3.7 Valid categories for the use of the Infrared-Rotisserie
Country
Country Specification Category
Pressure Gasconnect
Germany
DE:
II
2ELL3B/P
20, 50 mbar
Austria
AT:
II
2H3B
/P
20, 50 mbar
Italy
IT:
I
2H
20 mbar
Portugal
PT:
I
2H
20 mbar
Spain
ES:
I
2H
20 mbar
Sweden
SE:
II
2H3B/P
20, 30 mbar
Switzerland
CH:
II
2H3B/P
20, 50 mbar
Netherland
NL:
II
2L3P,
II
2L3B/P
25, 30, 50 mbar
Danmark
DK:
II
2H3B/P
20, 30 mbar
Finland
FI:
II
2H3B/P
20, 30 mbar
Ireland
IE:
I
2H
20 mbar
Great Britain
GB:
I
2H
20 mbar
Norway
NO:
II
2H3B/P
20, 30 mbar
Belgium
BE:
I
2E
I
3P
20, 50 mbar
France
FR:
II
2E+3B/P
20/25, 50 mbar
Iceland
IS
II
2H3B/P
20, 30 mbar
Czech Republic
CZ
II
2H3B/P
20, 30 mbar
3.3.8 Nameplate
The installation and operation manual is made for the Ubert Infrared Rotisserie of the model series
RT with the categories of natural and propane mentioned under point 3.3.7. The units correspond
to kind of construction "B11".
The type plate is fixed on the front side of the unit and bears the following indications:
- Serial number, type
- Order number kind of construction acc. to DIN-EN 203
A B
- Applicable for natural gas H/L and fluid gas
-
Category
- Adjusted for natural gas H mbar
- Adjusted for natural gas L mbar
- Adjusted for fluid gas
mbar
- Heat Load
kW
- Adjustment pressure
pressure control
mbar
- Consumption:
natural gas H
m³/h
- natural gas L
m³/h
- fluid gas
kg/h
- Power:
kW
- Electrical connection.:
V
N Hz
- 0085
3.3.9 Construction of the Infrared-Rotisserie and equipment
The unit is an Infrared Rotisserie with atmospheric main burners and chicken spits which are driven
by a motor chain gear. The gas connection is at the lower right side of the unit. The temperature
control is made by multiple adjustment valves with thermoelectrical ignition safety device (fully igni-
tion safe gas armatures). The operation temperature can be adjusted infinitely variable from the
minimum adjustment to the maximum adjustment. Motor and illumination are switched on or off by
turning cam switches.
Содержание RT Series
Страница 1: ...User Manual Infrared Rotisserie RT Series...
Страница 2: ......
Страница 27: ...Maintenance 27 printed 03 2012 Subject to change RTUserManual doc 6 4 Declaration of Conformity...