Uberhaus MPG-10CRN1-BH9 Скачать руководство пользователя страница 7

OPERATING INSTRUCTIONS

Operating Instructions

-    Press the  "MODE" button until the  "COOL" 
     indicator light comes on. 
-    Press the  ADJUST buttons "

" or "    " to 

     select your desired room temperature. The
     temperature can be set within a range of 

O

O

O

O

     17 C-30 C/62 F-86 F.
-    Press the "FAN SPEED" button to choose
     the fan speed. 

-    Press the  "MODE" button until the "DRY"
     indicator  light comes on.

COOL operation

DRY operation

-    Press the  "MODE" button until the
    "FAN " indicator  light comes on. 
-    Press the "FAN SPEED" button to 
     choose the fan speed. The temperature
     cannot be adjusted.
-    Do not put the duct to window.

FAN peration

TIMER operation

operation depen-
you have 

-

When the unit is on, first press the

Timer button, the TIMER OFF
indicator light illuminates. It indi-
cates the Auto Stop program is
initiated.

 -

-

Press or hold the UP or DOWN

button to change the Auto time in
0.5 hour increments, up to 10 hours,
then in 1 hour increments up to 24
hours. The control will count down
the time remaining until start.

-

The selected time will register in 5

seconds and the system will autom-
atically revert back to display the
previous temperature setting.

- Turning the unit ON or OFF at any

time or adjusting the timer setting
to 0.0 will cancel the Auto Start/
Stop timer program.

-

When a malfunction (E1 or E2)

occurs, the Auto Start/Stop timed
program will also be cancelled.

When the unit is off, first press the

Timer button, the TIMER ON indic-
ator light illuminates. It indicates
the Auto Start program is initiated.

-    The air conditioner will control room 
      temperature automatically to reach the setting
-    Under AUTO mode, you can not 
     select the fan speed.

-    Under this mode, you cannot select a fan 
     speed or adjust the temperature.
-    Keep windows and doors closed for the
     best dehumidifying effect.
-    Do not put the duct to window.

E2-

Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.

E4-

Display panel communication error-
Unplug the unit and plug it back in.
If error repeats, call for service.

P1-

Bottom tray is full - Connect the
drain hose and drain the collected
water away. If error repeats, call
for service.

Error codes:
E1-

Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.

To activate the FOLLOW ME feature,
the indicator light flashes.

9

FOLLOW ME indicator 

FOLLOW M E operation

AUTO operation

-    When you set the air conditioner in 

mode, it will automatically select 

heating(in some models only),

This feature can be activated
from the remote control ONLY.
The remote control serves as a
remote thermostat allowing for
the precise temperature control
at its location.

To activate the Follow Me feature,
point the remote control towards
the unit and press the Follow Me
button. The light on the unit control

NOTE:

 When more than one errors occur, 

            the priority of the code display order is: 
             E4--E2--E1--P1.

7

AUTO

cooling,

or fan only

ding on what temperature

selected and the room temperature.

Содержание MPG-10CRN1-BH9

Страница 1: ...87795001 MPG 10CRN1 BH9 3 s...

Страница 2: ...erating condition 3 Electrical information 4 Accessories 4 Names of parts 5 Electronic control operating instructions 6 Operating instructions 7 Location 9 Window kit installation 9 Exhaust hose insta...

Страница 3: ...Never use this appliance if it is not working properly or if it has been dropped or damaged Never use the plug to start and stop the unit Always use the switch on the control panel Do not cover or obs...

Страница 4: ...ner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electr...

Страница 5: ...omatically Carrying Handle both sides 1 2 3 Fig 1 Fig 2 Rear 6 7 8 9 10 11 Upper Air Filter Behind the grille Air Outlet Wheel Air intake Drain Outlet Air intake Lower Air Filter Behind the grille 12...

Страница 6: ......

Страница 7: ...imer button the TIMER ON indic ator light illuminates It indicates the Auto Start program is initiated The air conditioner will control room temperature automatically to reach the setting Under AUTO m...

Страница 8: ...tion adjustment Fig 4 SLEEP operation Press this button the set temperature will increase O O cooling or decrease heating by 1 C 2 F in 30 minutes The set temperature will then increase O O cooling or...

Страница 9: ...unded socket Never place any obstacles around the air inlet or outlet of the unit Allow at least 1 ft 30 cm of space from the wall for efficient air conditioning see Fig 5 Your window slider kit has b...

Страница 10: ...en the adjustable window kit if the width of window is less than 27 inches Open the window sash and place the window slider kit on the foam seal B Fig 9 3 Cut the foam seal adhesive type to the proper...

Страница 11: ...if the width of window is less than 27 inches Open the window sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the proper length and attach it...

Страница 12: ...installation 2 Push the Exhaust hose into the air outlet opening along the the arrow direction See Fig 18 IMPORTANT DO NOT OVER BEND THE DUCT SEE Fig 20 Fig 17 Fig 18 Fig 20 The exhaust hose can be in...

Страница 13: ...r Please refer to Fig 21 22 When the water level of the bottom tray reaches a predetermined level Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away...

Страница 14: ...air filter after cleaning and install the lower filter by using the screw 2 Unit enclosure Use a lint free cloth soaked with neutral detergent to clean the unit enclosure Finish with a dry clean cloth...

Страница 15: ...eat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocked by dust 2 Not cool enough Place the unit on a flat level ground if possib...

Страница 16: ...g into the remote controller Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not...

Страница 17: ...TIME Button Push the button to increase the indoor temperature 3 SWING Button on some models Push this button the louver will swing up and down automatically Push it again to stop Remote Controller F...

Страница 18: ...nt settings are locked in and the remote controller does not accept any operation except that of the LOCK Press again to cancel the LOCK mode 10 12 CANCEL Button a If the TIMER ON TIMER ON OFF or TIME...

Страница 19: ...button again to remove The clock time is indicated only when no AUTO ON OFF timer is set When AUTO TIMER feature is operating it displays the AUTO ON OFF time To check the current time press the CLOCK...

Страница 20: ...al Setting or the Clock When the right time is achieved press the CLOCK button or release the or and wait for 5 seconds the clock time stops flashing and the clock starts operating Press the CLOCK but...

Страница 21: ...he desired conditions manually When you select the AUTO mode you do not have to set the fan speed The fan speed will be automatically controlled When you set the air conditioner in AUTO mode it will a...

Страница 22: ...ME button Push the TEMP TIME button to set the desired temperature from 3 ON OFF button When the remote controller is off push this button to start the air conditioner ON OFF button Push this button a...

Страница 23: ...MER ON or TIMER OFF indicator and will flash 2 TEMP TIME button Press to set the desired time Forward Backward Press or hold the forward or backward button to change the Auto time by 0 5 hour incremen...

Страница 24: ...unit to turn on automatically before you return home The air conditioner will automatically start operating at the set time IMPORTANT The time will be registered within a 3 second period after pressi...

Страница 25: ...ED TIMER Setting both ON and OFF timers simultaneously Example TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop...

Страница 26: ...e Controller away from all liquids 6 Protect the Remote Controller from high temperatures and exposure radiation 7 Keep the indoor receiver out of direct sunlight or the Air Conditioner malfunction 8...

Страница 27: ...stions please contact our toll free service line at 1 866 206 0888 from 8 AM to 6 PM Monday to Friday Eastern time The product is guaranteed for 36 months if used for normal trade purposes and is vali...

Отзывы: