To prevent injury to the user or other people and property damage, the following  instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage. 

   Your air  conditioner should be used in such a way 
    that it is protected from moisture. e.g. condensation, 
   splashed water, etc. Do not place or store your air 
   conditioner  where it can fall or be pulled into water 
   or any other liquid. Unplug immediately should it 

   Always transport your air conditioner in a vertical 
   position and stand on a stable, level surface during 
   use. 
   Turn off the product when not in use.
   Always contact a qualified person to carry out 
   repairs. If the supply cord is damaged it must be 
   repaired by a qualified repairer.
   Keep an air path of at least 1 ft (30cm) all around 
   the unit  from walls, furniture and curtains.
   If the air conditioner is knocked over during use, 
   turn off  the unit and unplug from the mains supply
   immediately.
   
    
   

SAFETY PRECAUTIONS

!

Always do this

   Do not operate your air conditioner in a wet room
   such as a bathroom or laundry room.
   Do not touch the unit with wet or damp hands or 
   when barefoot.
   Do not press the buttons on the control panel with
   anything other than your fingers.
   Do not remove any fixed covers. Never use this 
   appliance if it is not working properly, or if it has
   been dropped or damaged.
   Never use the plug to start and stop the unit. 
   Always  use the switch on the control panel.
   Do not cover or obstruct the inlet or outlet grilles.
   Do not use hazardous chemicals to clean or come
   into contact with the unit. Do not use the unit in the
   presence of inflammable substances or vapour such
   as alcohol, insecticides, petrol,etc.
   Do not allow children to operate the unit 
   unsupervised.
   Do not use this product for functions other than
   those described in this instruction manual.

Never do this

Energy Save

Use the unit  in the recommended room size.
Locate the unit where furniture cannot obstruct the air flow.
Keep blinds/curtains closed during the sunniest part pf the day.
Keep the filters clean.
Keep doors and windows closed to keep cool air in and warm air out.

The air conditioner must be operated within the  temperature range indicated below:

Operating condition

Safety rules

Suggested tools for window kit installation

1. Screwdriver(medium size Phillips)            
2. Tape measure or ruler 
3. Knife or scissors
4. Saw(In the event that the window kit needs to be cut down in size because 
     the window is too narrow for direct installation)

MODE

ROOM TEMPERATURE

COOL

DRY

O

O

O

O

17 C(62 F)~35 C(95 F)

O

O

O

O

13 C(55 F)~35 C(95 F)

HEAT(heat pump type)

O

O

O

O

5 C(41 F)~30 C(86 F)

HEAT(electrical heat type)

O

O

<30 C/86 F

3

   come in contact with liquids.

Содержание MPG-10CRN1-BH9

Страница 1: ...87795001 MPG 10CRN1 BH9 3 s...

Страница 2: ...erating condition 3 Electrical information 4 Accessories 4 Names of parts 5 Electronic control operating instructions 6 Operating instructions 7 Location 9 Window kit installation 9 Exhaust hose insta...

Страница 3: ...Never use this appliance if it is not working properly or if it has been dropped or damaged Never use the plug to start and stop the unit Always use the switch on the control panel Do not cover or obs...

Страница 4: ...ner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electr...

Страница 5: ...omatically Carrying Handle both sides 1 2 3 Fig 1 Fig 2 Rear 6 7 8 9 10 11 Upper Air Filter Behind the grille Air Outlet Wheel Air intake Drain Outlet Air intake Lower Air Filter Behind the grille 12...

Страница 6: ......

Страница 7: ...imer button the TIMER ON indic ator light illuminates It indicates the Auto Start program is initiated The air conditioner will control room temperature automatically to reach the setting Under AUTO m...

Страница 8: ...tion adjustment Fig 4 SLEEP operation Press this button the set temperature will increase O O cooling or decrease heating by 1 C 2 F in 30 minutes The set temperature will then increase O O cooling or...

Страница 9: ...unded socket Never place any obstacles around the air inlet or outlet of the unit Allow at least 1 ft 30 cm of space from the wall for efficient air conditioning see Fig 5 Your window slider kit has b...

Страница 10: ...en the adjustable window kit if the width of window is less than 27 inches Open the window sash and place the window slider kit on the foam seal B Fig 9 3 Cut the foam seal adhesive type to the proper...

Страница 11: ...if the width of window is less than 27 inches Open the window sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the proper length and attach it...

Страница 12: ...installation 2 Push the Exhaust hose into the air outlet opening along the the arrow direction See Fig 18 IMPORTANT DO NOT OVER BEND THE DUCT SEE Fig 20 Fig 17 Fig 18 Fig 20 The exhaust hose can be in...

Страница 13: ...r Please refer to Fig 21 22 When the water level of the bottom tray reaches a predetermined level Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away...

Страница 14: ...air filter after cleaning and install the lower filter by using the screw 2 Unit enclosure Use a lint free cloth soaked with neutral detergent to clean the unit enclosure Finish with a dry clean cloth...

Страница 15: ...eat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocked by dust 2 Not cool enough Place the unit on a flat level ground if possib...

Страница 16: ...g into the remote controller Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not...

Страница 17: ...TIME Button Push the button to increase the indoor temperature 3 SWING Button on some models Push this button the louver will swing up and down automatically Push it again to stop Remote Controller F...

Страница 18: ...nt settings are locked in and the remote controller does not accept any operation except that of the LOCK Press again to cancel the LOCK mode 10 12 CANCEL Button a If the TIMER ON TIMER ON OFF or TIME...

Страница 19: ...button again to remove The clock time is indicated only when no AUTO ON OFF timer is set When AUTO TIMER feature is operating it displays the AUTO ON OFF time To check the current time press the CLOCK...

Страница 20: ...al Setting or the Clock When the right time is achieved press the CLOCK button or release the or and wait for 5 seconds the clock time stops flashing and the clock starts operating Press the CLOCK but...

Страница 21: ...he desired conditions manually When you select the AUTO mode you do not have to set the fan speed The fan speed will be automatically controlled When you set the air conditioner in AUTO mode it will a...

Страница 22: ...ME button Push the TEMP TIME button to set the desired temperature from 3 ON OFF button When the remote controller is off push this button to start the air conditioner ON OFF button Push this button a...

Страница 23: ...MER ON or TIMER OFF indicator and will flash 2 TEMP TIME button Press to set the desired time Forward Backward Press or hold the forward or backward button to change the Auto time by 0 5 hour incremen...

Страница 24: ...unit to turn on automatically before you return home The air conditioner will automatically start operating at the set time IMPORTANT The time will be registered within a 3 second period after pressi...

Страница 25: ...ED TIMER Setting both ON and OFF timers simultaneously Example TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop...

Страница 26: ...e Controller away from all liquids 6 Protect the Remote Controller from high temperatures and exposure radiation 7 Keep the indoor receiver out of direct sunlight or the Air Conditioner malfunction 8...

Страница 27: ...stions please contact our toll free service line at 1 866 206 0888 from 8 AM to 6 PM Monday to Friday Eastern time The product is guaranteed for 36 months if used for normal trade purposes and is vali...