Ubiflux W300(+) / W400(+) / W450(+)
7.2 Setting the air flow rate
The factory supplies the Ubiflux for the Ubiflux W300 flow rates
set to 50, 100, 150 en 225 m
3
/h and for the Ubiflux W400 /
W450 set to 50, 100, 200 and 300 m
3
/h respectively. The per
-
formance and the energy consumption of the Ubiflux depend
on the pressure drop in the duct system as well as on the filter
resistance.
Important:
Mode
:
is 0 or 50 m
3
/h (not in combination with a 3-way
switch).
Mode 1: must always be lower than mode 2.
Mode 2: must always be lower than mode 3;
Mode 3: Ubiflux W300 - adjustable between 50 and 300 m
3
/h;
Ubiflux W400 - adjustable between 50 and 400 m
3
/h;
Ubiflux W450 - adjustable between 50 and 450 m
3
/h;
If these conditions are not complied with, the air flow rate of the
higher mode will automatically be adjusted.
See the settings menu, §6.3, for changing the flow rates.
Putting into operation
Chapter 7
7.4 Factory setting
It is possible to reset all modified settings back to factory set
-
ting in one go.
All modified settings will be at the values they had when the
Ubiflux was supplied from the factory; all message codes / fault
codes will be erased from the service menu as well.
The filter
notification process will not reset.
7.3 Other settings installer
Various other settings of the Ubiflux can also be modified. How
to modify these is explained in §6.3.
operating mode
3 sec. visible
press > 10 sec.
simultaneously