Chapter 5
Installation
• Arrange the exterior air supply from the shadowed side of
the dwelling, preferably from the wall or overhang. If the out
-
door air is sucked in from under the tiles, it must be ensured
that no condensation develops in the roof boarding and no
water can run in. Ventilation air can be sucked in from under
the tiles if air can access freely at the top and the bottom of
the roof area and the sewage vent stack does not end under
the tiles.
• Feed the extract duct through the roof boarding in such a
manner that no condensation develops in the roof boarding.
• Install the extract duct between the Ubiflux and the roof slee
-
ve in such a manner that surface condensation is prevented.
• Always use an insulated ventilation roof sleeve.
• The maximum permissible resistance in the duct system is
150 Pa (W300 & W400) and 100 Pa (W450) at the maximum
ventilation capacity. If the resistance of the duct system is
higher, the maximum ventilation capacity will be lower.
• The location of the mechanical ventilation output and the se
-
wer stack vent relative must be chosen to prevent nuisance.
• Choose the location of the supply valves to prevent fouling
and draught. We recommend to use the Ubbink supply val
-
ves.
Install sufficient overflow openings, door gap 2 cm.
6265-B.pdf 21-3-2011 14:13:01
1 = Ubiflux left-handed 2/2 (place
level)
2 = Preferred ventilation air supply
3 = Ventilation air supply under the
tiles
4a = Free suction bottom roof area
4b = Free suction top roof area
5 = Sewer vent
6 = Preferred location extract venti
-
lation air; use Ubbink insulated
ventilation roof sleeve.
7 = Ubbink synthetic high efficiency
heat recovery duct
8 = Condensate discharge
9 = Acoustic duct
10 = Ducts from and to dwelling
A = Spacing 10 mm above roof deck
B = Roof insulation
C = Seal with foam
D = Pipe for make-up air to be carefully insulated and provi-
ded with vapour barrier
1 = Ubbink supply valves
2 = Supply from wall
3 = Suction valve in ceiling or high in wall
4 = Prevent crosstalk
5 = Preferably Ubbink incorporated ducts
a = Gap under the door 2 cm.
A
A = Minimum height > 60mm