37
Ubiflux W300(+) / W400(+) / W450(+)
Ubiflux W300(+) / W400(+) / W450+
38
Chapter 11
Electric connections accessories
11.7 Connecting external switch contact (only possible for U)
An external switch contact (e.g. switch or relay contact) can be connected to the U. This external switch contact can be con
-
nected to connections no. 1 and no. 2 of 9-pole connector X15; this 9-pole connector is directly accessible at the rear of the top without
having to dismount the display cover (see also §11.1).
If a second input is required as external switch contact, if necessary connections no. 3 and no. 4 of the 9-pole connector X15, which
as standard are preprogrammed as 0-10 volt input, can be reprogrammed as second input switch contact. Changing parameter 21
from “0” to “1” will turn this 0-10 V input into an input make contact. When using two switch inputs, switch contact 1 (X15-1 & X15-2)
always takes priority over switch contact 2 (X15-3 & X15-4).
E2367-B
Modifying parameter 18 enables, when closing the input external switch contact 1 X15-1 and X15-2, five different situations for the
extract fan to be set; dependent on the setting of parameters 19 and 20, the supply and extract fans can run at various flow rates
(highest flow rate is shown on the display).
When connections X15-3 and X15-4 are programmed as switch input 2, parameters 24, 25 and 26 can be used to set the various
situations the same as for contact input 1. When closing contact input 2, the display shows the text “CN2”.
1) Bypass conditions opening valve: - outdoor temperature is higher than 10°C.
- temperature from atmosphere is at least lower than temperature from dwelling.
- temperature from dwelling is higher than the preset bypass temperature (parameter 5).
A = U
B = + version control board
C = Contact connected to switch input 1; for
instance a switch or a relay contact
D = Display U (text “CN1” appears
when contact C is closed.)
Setting
Parameter 18
Function conditions
Situation supply fan extract fan
Setting parame-
ters 19 and 20
Action supply or extract fan when closing
contact inputs X15-1 & X15-2
0 (factory
setting
Contact input 1
15-1 & X15-2 closed
No action possible because contact input 1 has not been activated yet (parameter 18 is still at 0)
1
Contact input 1
15-1 & X15-2 closed
Action dependent on setting
supply fan (parameter 19) and
extract fan (parameter 20)
0
1
2
3
4
5
6
7
Fan switches off
Fan minimum flow rate (50m
3
/h)
Fan to flow rate mode 1
Fan to flow rate mode 2
Fan to flow rate mode 3
Fan to flow rate multiple switch
Fan to maximum flow rate
No fan activation
2
Contact input 1
15-1 & X15-2 closed
Satisfies bypass conditi
-
ons for valve open
1
3
Contact input 1
15-1 & X15-2 closed
The bypass valve opens; auto
-
matic bypass control in Ubiflux
is
overruled; action fans depen
-
dent on parameters 19 & 20.
4
Contact input 1
15-1 & X15-2 closed
The bedroom valves opens.
Bedroom valve 24 volt is con-
nected to X15-5 (24V GND)
X15-6 (24V +) and X15-9 (0-10
V control); action fans depen
-
dent on parameters 19 & 20.
9-pole connector X15