6. TROUBLESHOOTING
Motors for Blower or
Shaker Will Not Start
Supply Power Not Operational
Check input power to motor circuits for proper
voltage on all legs.
Check and correct internal motor wiring for
proper connections based on the incoming
line voltage. Check control voltage power
supply (i.e. fuses, transformer, overloads etc.).
Improper Electrical Wiring
Dust Emissions From
Clean Air Discharge
Filter Not Installed Properly
Check to make sure cambars are in the
upright and locked positions. Inspect gasket
on underside of tubesheet for damage.
Allow filters to seed during normal operation.
Emissions should dissipate after several hours
of dust loading.
New Filters are Not Seasoned
Insufficient Airflow
Blower Rotation is Reversed
All blower packages on the SDC should be
rotating clock-wise when looking at the drive
side of the motor.
Check to make sure the filter access door of
the cabinet is tightly closed. Check the drum
connection and ductwork between the process
and collector for leaking connections.
Leak Downstream of Collection Hood
The filters either need to be cleaned or are at
the end of their useful life.
Filters Plugged
Continual, Excessive
Pressure Drop
Shaker Cleaning System Not Functioning
Properly
Remove shaker mechanism access panel and
inspect. Make sure all connections are tight
and the drive shaft is securely attached to the
shaker fingers.
Empty drum and clean out hopper.
Dust Storage Drum is Full
The filters either need to be cleaned or are at
the end of their useful life.
Filters Plugged
Increase air inlet and/or duct size to minimize
static pressure losses. Follow ductwork design
methods as listed in
Industrial Ventilation
Manual
by American Conference of
Governmental Industrial Hygenists.
Air Inlet and/or Ducting is Undersized
PROBLEM
POSSIBLE CAUSE
RECOMMENDED SOLUTIONS
Содержание CLARCOR SDC Series
Страница 1: ...Shaker Dust Collector l SDC Series OWNER S MANUAL ...
Страница 14: ...10 Revised 10 15 SDC Shaker Dust Collector Figure 9 Wiring Diagram 04 2611 01A ...
Страница 15: ...11 Revised 10 15 SDC Shaker Dust Collector Figure 10 Interconnect Diagram 04 2610 01 ...
Страница 22: ...This page intentionally left blank ...
Страница 23: ...This page intentionally left blank ...