http://u-prox.com
22
Connecting an external reader
The panel has a port for external readers. Only U-Prox series reader may be used
with panel as external. The connection of U-Prox Mini RF ID reader is depicted on
Fig.14.
Fig 14.
Connecting an external reader
Color matching circuits:
White - data 1
Green - data 0
Black
– GND
Red - +12
Current consumption of each external reader connected to terminals "12 V" should
not exceed 100 mA. When connecting to panel a reader of long range with current
consumption more than 100 mA, supply the voltage to it from the separate source.
Connecting Loop Control
Panel has two inputs for connecting the loops supervised with end of line resistors.
Each input functionality programmable. Inputs' functions are:
Door Contact
RTE
Door C RTE
Free pass (A, B, A+ B)
Blocking (A, B, A +B)
Sensors monitoring
220V control and battery
The following describes how to connect various types of inputs. After factory reset all
loops have no purpose and are not supervised. All loops work both for closing and
opening.
The use of load resistors is mandatory.
Normal state of the loop - from 1.4 kOm to 3kOm, Line shortage - less than 1.4 kOm,
the broken line - more than 3 kOm.