background image

14 

 

FCC  Caution:  Any  changes  or  modifications  not  expressly  ap-

proved  by  the  party  responsible  for  compliance  could  void  the 

user's authority to operate this equipment. 

 

This device complies with Part 15 of the FCC Rules. Operation is sub-

ject  to  the  following  two  conditions:  (1)  This  device  may  not  cause 

harmful  interference,  and  (2)  this  device  must  accept  any  interference 

received, including interference that may cause undesired operation. 

 

IMPORTANT NOTE: 

 

FCC Radiation Exposure Statement: 

This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth 

for  an  uncontrolled  environment.  This  equipment  should  be  installed 

and operated with minimum distance 20cm between the radiator & your 

body. The antenna(s) used for this transmitter must not be co-located or 

operating in conjunction with any other antenna or transmitter. 

 

Limited Warranty 

All Tycon Systems products are supplied with a limited 12 month war-

ranty which covers material and workmanship defects. This warranty 

does not cover the following:  

▫ 

Parts requiring replacement due to improper installation, 

misuse, poor site conditions, faulty power, etc. 

▫ 

Lightning damage. 

▫ 

Physical damage to the external & internal parts. 

▫ 

Products that have been opened, altered, or defaced. 

▫ 

Water damage for units that were not sealed or mounted 

according to user manual. 

▫ 

Units that were not properly grounded. 

▫ 

Usage other than in accordance with instructions and the 

normal intended use. 

Do not return any products until you receive a Return Material Authori-

zation (RMA) number. Products received without a valid RMA number 

will be rejected and returned to sender.  

 

 

Warranty Repairs 

All returns must have a valid RMA number written clearly on the outside 

of the box. Without an RMA number the shipment will be refused. For 

customers  located  in  United  States  and  Canada,  customer  pays  all 

shipping charges incurred to ship the product to Tycon Systems.  Tycon 

Systems pays shipping charges to return the product to the original pur-

chaser. For all other countries, the original purchaser shall pay all ship-

ping, broker fees, duties and taxes incurred in shipping products to and 

from  Tycon  Systems.    Provided  the  goods  have  not  been  modified  or 

repair attempted by someone other than Tycon Systems, at the option 

Содержание EZ-BridgeLT-HD

Страница 1: ...ed Ethernet and Power for ultimate reliability Shielded CAT5 cables to protect against EMI Achieve up to 15 Mbit sec speed 20Mbps for 5GHz version Link up to 3 miles with good line of sight Plug and Play Simple Installation Best security available WPA Field Proven Wireless Technology ...

Страница 2: ... your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install the antenna on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet Make sure there are no people pets etc below when you are working on a roof or ladder Watch out for any power lines which may be overhead under ground ...

Страница 3: ...idge Qwik Install STEP 1 Choose a mounting location with good line of sight to the re mote location The supplied bracket can be mounted to a wall or to an existing pole up to 2 diameter If only short distances are needed the antenna can be mounted inside a building TECH TIP Microwaves travel in straight lines and they lose strength quickly when going thru buildings and trees If there are objects i...

Страница 4: ...able through the bottom cover and plug into the RJ45 Jack inside the unit Keep the black gasket material in the bottom of the cover to help keep out dust and insects STEP 6 Route shielded CAT5 cable from the antenna into the building Always create a strain relief near the antenna so the cable is not pulling directly on the antenna Use the CAT5 strain relief hook fea ture built into the housing bac...

Страница 5: ...u to change the IP address or set it as a DHCP client Just select the unit click on IP DETAILS make selections enter the user name and password and save changes directly to the device 3 SECURITY Security is pre configured with system passwords WPA2 encryption and Mac Address verification pre set This is so that you can setup a plug and play link and have confidence that the link is secure and that...

Страница 6: ...re the actual thruput by timing the transfer of data across the link One program that we have found useful for determining thruput is DISKBENCH http nodesoft com DiskBench Keep in mind that DiskBench displays speed in Bytes per second You have to multiply the results by 8 to get Bits per second 6 SITE SURVEY The site survey is a very useful tool to determine what wireless devices are within range ...

Страница 7: ...ntenna Gain 14 dBi 19 dBi Antenna Beamwidth H V 35 25 deg 21 10 deg Antenna Front to Back 20dB 23dB Polarization Vertical Vertical POE Specification Power Over Ethernet INPUT 100 240VAC 50 60Hz OUTPUT 15VDC 1A Mechanical Specifications Color White Dimensions L x W x H 12 4 x 7 3 x 2 5 314 x 187x 65mm System Weight 12 lb 5 4 kg Ethernet Connector RJ45 Mount Pole up to 2 dia or Wall Environmental Sp...

Страница 8: ...ximum of 6 buildings and for better perfor mance no more than 4 To add an EZ Bridge or EZ Go unit to the existing EZ Bridge network you set the operating mode to WDS and you program the remote units MAC address into the local units WDS table and the local units MAC address into the remote units WDS table The WDS table is found under WDS SETTINGS from the main menu after setting the device to WDS T...

Страница 9: ... be helped by moving the antenna to a new location with better line of site If signal level is good between 35 and 79dBm try chang ing the wireless channel on both units You should also do a site survey on both units to see what channels are already being used Select a channel that is not already used or one that has a very low signal strength Always change the channel on the remote unit first and...

Страница 10: ...e provides a seamless con nection between networks and you can share the internet access avail able on the main network with the remote network Please take note that certain internet service providers may not approve of this and in some cases they may consider this to be illegal It s best before shar ing your internet connection that you check with your internet service provider to make sure you a...

Страница 11: ...m support support htm for firmware updates C System Name Location and Contact These are user fields You can assign any useful information in these fields This can be useful for identifying where the unit is located like Mikes House or Barn D Mode This shows the current operating mode of the unit E Band Identifies what wireless frequency and protocol the unit is set for F SSID When the unit is set ...

Страница 12: ...client the unit will try to get it s IP ad dress from the upstream router It will only try to get it s IP address upon power up or upon making any changes to the unit configura tion If it doesn t get it s IP address it will revert to the IP address that is programmed into the unit P IP Address and Subnet Mask Displays the current IP address and subnet mask Q Default Gateway This setting is not use...

Страница 13: ...ons may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or re...

Страница 14: ...iring replacement due to improper installation misuse poor site conditions faulty power etc Lightning damage Physical damage to the external internal parts Products that have been opened altered or defaced Water damage for units that were not sealed or mounted according to user manual Units that were not properly grounded Usage other than in accordance with instructions and the normal intended use...

Страница 15: ...harge will be at the discretion of Tycon Systems The RMA number is valid for 14 days from date of issue The product must be received by the repair depot within these 14 days or the shipment may be refused Shipping and Damage Claims All shipping damage claims are the purchaser s responsibility Inspect each shipment upon delivery and IMMEDIATELY report all damage to the carrier There may be time lim...

Страница 16: ...16 8000011 Rev 4 EZ BridgeLT HD Qwik Install Guide ...

Отзывы: