background image

mins for reboot. 

8. 

UPGRADE FIRMWARE

: For the latest firmware point your 

browser to 

http://ez-bridge.com/support/support.htm

   Download the 

latest firmware to your PC. Select UPGRADE from the menu and then 

browse for the new file. 

9. 

CHANGING TO CLIENT

: The EZ-Bridge™ can be changed to a cli-

ent device on the WIRELESS|BASIC SETTINGS page. You might 

change to client if you wanted to have multiple units communicating 

with a single access point. If changing to client, make sure the BSSID 

field is changed to all zero’s or else client will lose connection with the 

AP after any reboot. 

10. 

CHANGING TO ACCESS POINT

: The EZ-Bridge™ can be 

changed to an access point device on the WIRELESS|BASIC SET-

TINGS page. You might want to change one unit to access point if you 

will have multiple clients bridging in a point to multipoint configuration. 

11. 

WDS MESH NETWORK

: You can add additional EZ-Bridge™ 

units or EZ-Go

®

 Network Expansion units to link 3 or more buildings 

together. We suggest maximum of 6 buildings and for better perfor-

mance, no more than 4. To add an EZ-Bridge™or EZ-Go

®

 unit to the 

existing EZ-Bridge network, you set the operating mode to WDS and 

you program the remote units MAC address into the local units WDS 

table and the local units MAC address into the remote units WDS table. 

The WDS table is found under WDS SETTINGS from the main menu 

after setting the device to WDS. The MAC address for each unit is 

found on the STATUS page or can be found using the Discovery Tool. 

When entering MAC’s you enter just the HEX characters without the 

“:” (colon) 

Advanced Features

 

The EZ-Bridge™ 

 

has many advanced features if more functionality is 

desired.  To access the advanced features, click on 

Advanced Web 

at 

the top of the menu tree. This will activate the advanced menu options.  

The EZ-Bridge™ can operate as Access Point, Client, WDS, AP+WDS, 

Point  to  Point. Go to WIRELESS  |  BASIC SETTINGS to change  wire-

less mode. Go to ETHERNET | IP SETTINGS to change network oper-

ation mode from Bridge (default) to Router. 

Since  documentation  for  these  advanced  modes  is  too  extensive  to 

cover  here  please  retrieve  the  documentation  online  at 

http://ez-

bridge.com/support/support.htm

 

Содержание EZ-BridgeLT-HD

Страница 1: ...ed Ethernet and Power for ultimate reliability Shielded CAT5 cables to protect against EMI Achieve up to 15 Mbit sec speed 20Mbps for 5GHz version Link up to 3 miles with good line of sight Plug and Play Simple Installation Best security available WPA Field Proven Wireless Technology ...

Страница 2: ... your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install the antenna on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet Make sure there are no people pets etc below when you are working on a roof or ladder Watch out for any power lines which may be overhead under ground ...

Страница 3: ...idge Qwik Install STEP 1 Choose a mounting location with good line of sight to the re mote location The supplied bracket can be mounted to a wall or to an existing pole up to 2 diameter If only short distances are needed the antenna can be mounted inside a building TECH TIP Microwaves travel in straight lines and they lose strength quickly when going thru buildings and trees If there are objects i...

Страница 4: ...able through the bottom cover and plug into the RJ45 Jack inside the unit Keep the black gasket material in the bottom of the cover to help keep out dust and insects STEP 6 Route shielded CAT5 cable from the antenna into the building Always create a strain relief near the antenna so the cable is not pulling directly on the antenna Use the CAT5 strain relief hook fea ture built into the housing bac...

Страница 5: ...u to change the IP address or set it as a DHCP client Just select the unit click on IP DETAILS make selections enter the user name and password and save changes directly to the device 3 SECURITY Security is pre configured with system passwords WPA2 encryption and Mac Address verification pre set This is so that you can setup a plug and play link and have confidence that the link is secure and that...

Страница 6: ...re the actual thruput by timing the transfer of data across the link One program that we have found useful for determining thruput is DISKBENCH http nodesoft com DiskBench Keep in mind that DiskBench displays speed in Bytes per second You have to multiply the results by 8 to get Bits per second 6 SITE SURVEY The site survey is a very useful tool to determine what wireless devices are within range ...

Страница 7: ...ntenna Gain 14 dBi 19 dBi Antenna Beamwidth H V 35 25 deg 21 10 deg Antenna Front to Back 20dB 23dB Polarization Vertical Vertical POE Specification Power Over Ethernet INPUT 100 240VAC 50 60Hz OUTPUT 15VDC 1A Mechanical Specifications Color White Dimensions L x W x H 12 4 x 7 3 x 2 5 314 x 187x 65mm System Weight 12 lb 5 4 kg Ethernet Connector RJ45 Mount Pole up to 2 dia or Wall Environmental Sp...

Страница 8: ...ximum of 6 buildings and for better perfor mance no more than 4 To add an EZ Bridge or EZ Go unit to the existing EZ Bridge network you set the operating mode to WDS and you program the remote units MAC address into the local units WDS table and the local units MAC address into the remote units WDS table The WDS table is found under WDS SETTINGS from the main menu after setting the device to WDS T...

Страница 9: ... be helped by moving the antenna to a new location with better line of site If signal level is good between 35 and 79dBm try chang ing the wireless channel on both units You should also do a site survey on both units to see what channels are already being used Select a channel that is not already used or one that has a very low signal strength Always change the channel on the remote unit first and...

Страница 10: ...e provides a seamless con nection between networks and you can share the internet access avail able on the main network with the remote network Please take note that certain internet service providers may not approve of this and in some cases they may consider this to be illegal It s best before shar ing your internet connection that you check with your internet service provider to make sure you a...

Страница 11: ...m support support htm for firmware updates C System Name Location and Contact These are user fields You can assign any useful information in these fields This can be useful for identifying where the unit is located like Mikes House or Barn D Mode This shows the current operating mode of the unit E Band Identifies what wireless frequency and protocol the unit is set for F SSID When the unit is set ...

Страница 12: ...client the unit will try to get it s IP ad dress from the upstream router It will only try to get it s IP address upon power up or upon making any changes to the unit configura tion If it doesn t get it s IP address it will revert to the IP address that is programmed into the unit P IP Address and Subnet Mask Displays the current IP address and subnet mask Q Default Gateway This setting is not use...

Страница 13: ...ons may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or re...

Страница 14: ...iring replacement due to improper installation misuse poor site conditions faulty power etc Lightning damage Physical damage to the external internal parts Products that have been opened altered or defaced Water damage for units that were not sealed or mounted according to user manual Units that were not properly grounded Usage other than in accordance with instructions and the normal intended use...

Страница 15: ...harge will be at the discretion of Tycon Systems The RMA number is valid for 14 days from date of issue The product must be received by the repair depot within these 14 days or the shipment may be refused Shipping and Damage Claims All shipping damage claims are the purchaser s responsibility Inspect each shipment upon delivery and IMMEDIATELY report all damage to the carrier There may be time lim...

Страница 16: ...16 8000011 Rev 4 EZ BridgeLT HD Qwik Install Guide ...

Отзывы: