P o w e r S e r i e s   N e o   I n s t a l l a t i o n   G u i d e

4

Enrollment

All optional modules and devices must be enrolled on the system. During enrollment, the 

electronic serial number (ESN) of each device is identified to the control panel and zones 

are assigned. A wireless transceiver HSM2HOST or an RF keypad must be enrolled first 

before wireless devices can be enrolled. 

Enrolling Modules

During automatic and manual enrollment, if an attempt is made to enroll more than the 

maximum number of modules, an error tone sounds and a message is displayed on LCD 

keypads. 

Table 1-5 Module Capacity

Modules can be enrolled automatically or manually using section [902] of Installer pro-

gramming. 
To confirm that a module has been successfully enrolled, use Installer Programming sec-

tion [903].

Enroll Wireless Devices

Wireless devices are enrolled via the wireless transceiver module and Installer Program-

ming section [804][000].

Auto Enrollment

To enroll a wireless device using this method, press and hold the Enroll button on the 

device for 2-5 seconds until the LED lights then release the button. The alarm panel auto-

matically recognizes the device and the keypad displays a confirmation message. The 

device ID and next available zone number are displayed. Press [*] to accept or scroll to 

another available zone number. 

Pre-Enrollment

Pre-enrollment is a two step process. The first step requires entering each device ID 

([804][001]-[716]). Every wireless device has an ID printed on the sticker attached to the 

device. The format is XXX-YYYY where: 

XXX identifies the type or model of the device

YYYY is a short encrypted ID used by the system to identify the specific device

Pre-enrollment can be done at a remote location and using DLS. The second step is to 

press the enrollment button on the device, usually done on location. Installer Programming 

does not have to be entered at this step. Both steps must be performed in order to complete 

the enrollment.

Programming Methods

The alarm system can be programmed using the following methods:

Table 1-6 Programming Methods

Viewing Programming

Programming sections can be viewed from any system keypad. The method for viewing 

and selecting programming options using LCD, LED and ICON keypads depends on the 

keypad type used.
Generally, programming options are accessed in the following way:

1.

Enter Installer Programming mode ([*][8]).

2.

Navigate to a specific programming section.

3.

Select an option to view or change it’s programming.

All programming options are numbered and can be accessed by navigating through the 

menu (LCD) or by keying in the program section number. 
For toggle options, the name of the option is displayed (LCD) or LEDs 1-8 are illuminated 

(LED and ICON). 

Use the keypad numbers to toggle options on or off. Sections requiring data input, such as 

phone numbers, display the full data in fields up to 32 characters long (LCD). To input 

data, use the scroll keys to select a character then press the keypad button corresponding to 

the number/letter required. Scroll to the next character and repeat the procedure as needed.
Press the [#] key to save changes and exit the program section.

Minimum Required Programming

Once basic installation of the alarm panel is complete, the following general configuration 

options can be set.

[000] Language Selection

(LCD keypads only)
Use this section to set the language displayed by LCD keypads. To select a language:

1.

Enter Installer Programming: [*][8][Installer Code].

2.

Enter programming section [000]>[000].

3.

Key in the 2-digit number corresponding to the language required. See below:

Time and Date

Use this section to program the alarm system clock. 
Menu: [*][6][master code] > Time and Date
Keypad: [*][6][master code] + 01
Enter time and date using the following format: (HH:MM); (MM-DD-YY). Valid time 

entries are 00-23hours, 00-59 minutes. Valid date entries are 1-12 months, 1-31 days.

Setting Up a Partition

Partitions are added or removed from the system by applying or removing a partition mask 

via Installer Programming section [200]. The number of available partitions depends on 

the alarm panel model.

Bell/Siren Operation

Each partition must have a siren. The system siren connected to the bell output of the 

alarm controller can be mounted in a central location within hearing range of all partitions. 

Each partition can also have wireless sirens activated only on the assigned partition. 

Keypad Partition Setup

Keypads can be configured to control an individual partition or all partitions. 

1.

Enter Installer Programming [*][8][installer code].

2.

Select [861]-[876] to program keypads 1-16.

• Press [000] for partition assignment.
• For global operation, key in 00.
• To assign a keypad to a partition, key in 01-08 for partition 1-8.

3.

Press the [#] key twice to exit programming. 

Continue this procedure at each keypad until all have been programmed.

Users are assigned partition access rights via the [*][5] menu. 

Assign sirens to partitions:

[804]>[000]>[551]-[556]>[000]

Set up partition account codes:

[310]>[001]-[008]

Set up partition timers:

Entry/exit delay, settle delay – [005]>[001]-[008]

Automatic arming/disarming schedule – [151]-[158]>[001]/[002]

Auto disarming holiday schedule – [151]-[158]>[003] 

No activity arming – [151]-[158]>[006]

Automatic clock adjust – [005]>[000], option 6

Delay between dialing attempts – [377]>[012]

Module

HS2016

HS2032

HS2064

HS2128

HSM2108  8  Zone  expander 

1

3

7

15

HSM2208  8  Output  expander

2

4

8

16

Wireless Keypad:
HS2LCDRF(P)4
HS2ICNRF(P)4
HS2LCDWF(P)(V)4 

8

8

8

16

HSM2300  Power  Supply  1A 

3

3

3

4

HSM2204  4  High  Current  Output

1

1

3

4

HSM2HOSTx  Transceiver

1

1

1

1

PC5950 Audio Verification
(not UL evaluated)

1

1

1

1

Method

Description

Procedure

Template 
programming

Use pre-defined templates to 
quickly apply basic pro-
gramming and to set up DLS 
downloading.

Press [899] at the “Enter Section” 
screen.
See the PowerSeries Neo Refer-
ence Manual for details.

DLS 
programming

Download and apply pro-
gramming using DLS-5™ 
(v.1.3 or higher) software.

For local DLS, use a PC-Link cable 
and laptop with DLS-5 software 
installed.
For remote DLS, use a telephone 
line, cellular network or the Inter-
net.

Installer 
programming

Manually program all alarm 
system and device options.

Press [*][8][installer code] while 
the system is disarmed.

01 = English

11 = Swedish

21 = Russian

02 = Spanish

12 = Norwegian

22 = Bulgarian

03 = Portuguese

13 = Danish

23 = Latvian

04 = French

14 = Hebrew

24 = Lithuanian

05 = Italian

15 = Greek

25 = Ukrainian

06 = Dutch

16 = Turkish

26 = Slovakian

07 = Polish

18 = Croatian

27 = Serbian

08 = Czech

19 = Hungarian

28 = Estonian

09 = Finnish

20 = Romanian

29 = Slovenian

10 = German

firealarmresources.com

Содержание DSC PowerSeries neo

Страница 1: ...t Test the panel completely to ensure that all features and functions operate as programmed 901 Walk Test 904 000 Wireless Placement Test Modules Wireless keypads HS2LCDWFxUL HS2LCDWFPxUL HS2LCDWFPVxU...

Страница 2: ...lephone connection e Do not route any wiring over circuit boards f The installer must ensure that a readily accessible disconnect device is incorporated into the building for permanently connected ins...

Страница 3: ...sistors When double end of line DEOL resistors are installed at the end of a zone loop the sec ond resistor enables the panel to determine if the zone is in alarm tampered or faulted Diagram 1 4 DEOL...

Страница 4: ...quired Programming Once basic installation of the alarm panel is complete the following general configuration options can be set 000 Language Selection LCD keypads only Use this section to set the lan...

Страница 5: ...ication 9 Normally Closed EOL 10 Single EOL 11 Double EOL 12 Fast Normal Loop Response Trouble Detailed Trouble 01 Service Required 01 Bell circuit 02 RF jam detected 03 Aux supply trouble 04 Time and...

Страница 6: ...on PGM2 being used as a 2 wire smoke detector input This trouble is generated by a short on hardwired zones when DEOL is used Ensure a 2 2K EOL resistor is connected red red red Remove wire leads from...

Страница 7: ...led in the same enclosure and configured as primary or back up with AES 128 bit encryption Compliant with EN50136 1 1 EN50136 2 1 ATS2 requirements Trouble 10 Module Tamper Press 10 to determine speci...

Страница 8: ...03 Maintenance Code AAAA00 PGM Programming 007 PGM Programming 000 Main Bell Partition Assignment 1 Partition 1 2 Partition 2 3 Partition 3 4 Partition 4 5 Partition 5 6 Partition 6 7 Partition 7 8 Pa...

Страница 9: ...Thursday Friday Saturday 003 Auto Disarming Holiday Schedule Holiday 1 Holiday 2 Holiday 3 Holiday 4 004 Auto Arming Pre Alert 004 005 Auto Arming Postpone Timer 000 006 No Activity Arming Timer 000...

Страница 10: ...g 4 Pulse Dial After 5th Attempt 5 Parallel Communications 6 Alternate Dial 7 Reduced Dialing Attempts 8 Activity Delinquency 381 Communicator Option 2 1 Keypad Ringback 2 Bell Ringback 4 Closing Conf...

Страница 11: ...may not remove any proprietary notices marks or labels from the Software Product You shall institute reasonable measures to ensure compliance with the terms and conditions of this EULA b Separation of...

Страница 12: ...80 017 081 018 082 019 083 020 084 021 085 022 086 023 087 024 088 025 089 026 090 027 091 028 092 029 093 030 094 031 095 032 096 033 097 034 098 035 099 036 100 037 101 038 102 039 103 040 104 041 1...

Страница 13: ...Wireless Device Record Installer Defined Access Codes System Account Code Module Type Slot Serial Number Module Type Slot Serial Number Device Type Zone Serial Number Device Type Zone Serial Number 0...

Страница 14: ...Fire Installations section 001 fire zone shall be programmed as type 025 The entry delay shall not exceed 45 seconds refer to section 005 The exit delay shall not exceed 60 seconds refer to section 00...

Страница 15: ...s of time Also an intruder may cut the telephone line or defeat its operation by more sophisticated means which may be difficult to detect Insufficient Time There may be circumstances when the system...

Страница 16: ...entry and exit delays and bell time out for the system Note Combined entry delay and communications delay abort window shall not exceed 60s Range 30 sec to 4 min Default 30 sec Required programmable A...

Отзывы: