P o w e r S e r i e s N e o I n s t a l l a t i o n G u i d e
4
Enrollment
All optional modules and devices must be enrolled on the system. During enrollment, the
electronic serial number (ESN) of each device is identified to the control panel and zones
are assigned. A wireless transceiver HSM2HOST or an RF keypad must be enrolled first
before wireless devices can be enrolled.
Enrolling Modules
During automatic and manual enrollment, if an attempt is made to enroll more than the
maximum number of modules, an error tone sounds and a message is displayed on LCD
keypads.
Table 1-5 Module Capacity
Modules can be enrolled automatically or manually using section [902] of Installer pro-
gramming.
To confirm that a module has been successfully enrolled, use Installer Programming sec-
tion [903].
Enroll Wireless Devices
Wireless devices are enrolled via the wireless transceiver module and Installer Program-
ming section [804][000].
Auto Enrollment
To enroll a wireless device using this method, press and hold the Enroll button on the
device for 2-5 seconds until the LED lights then release the button. The alarm panel auto-
matically recognizes the device and the keypad displays a confirmation message. The
device ID and next available zone number are displayed. Press [*] to accept or scroll to
another available zone number.
Pre-Enrollment
Pre-enrollment is a two step process. The first step requires entering each device ID
([804][001]-[716]). Every wireless device has an ID printed on the sticker attached to the
device. The format is XXX-YYYY where:
•
XXX identifies the type or model of the device
•
YYYY is a short encrypted ID used by the system to identify the specific device
Pre-enrollment can be done at a remote location and using DLS. The second step is to
press the enrollment button on the device, usually done on location. Installer Programming
does not have to be entered at this step. Both steps must be performed in order to complete
the enrollment.
Programming Methods
The alarm system can be programmed using the following methods:
Table 1-6 Programming Methods
Viewing Programming
Programming sections can be viewed from any system keypad. The method for viewing
and selecting programming options using LCD, LED and ICON keypads depends on the
keypad type used.
Generally, programming options are accessed in the following way:
1.
Enter Installer Programming mode ([*][8]).
2.
Navigate to a specific programming section.
3.
Select an option to view or change it’s programming.
All programming options are numbered and can be accessed by navigating through the
menu (LCD) or by keying in the program section number.
For toggle options, the name of the option is displayed (LCD) or LEDs 1-8 are illuminated
(LED and ICON).
Use the keypad numbers to toggle options on or off. Sections requiring data input, such as
phone numbers, display the full data in fields up to 32 characters long (LCD). To input
data, use the scroll keys to select a character then press the keypad button corresponding to
the number/letter required. Scroll to the next character and repeat the procedure as needed.
Press the [#] key to save changes and exit the program section.
Minimum Required Programming
Once basic installation of the alarm panel is complete, the following general configuration
options can be set.
[000] Language Selection
(LCD keypads only)
Use this section to set the language displayed by LCD keypads. To select a language:
1.
Enter Installer Programming: [*][8][Installer Code].
2.
Enter programming section [000]>[000].
3.
Key in the 2-digit number corresponding to the language required. See below:
Time and Date
Use this section to program the alarm system clock.
Menu: [*][6][master code] > Time and Date
Keypad: [*][6][master code] + 01
Enter time and date using the following format: (HH:MM); (MM-DD-YY). Valid time
entries are 00-23hours, 00-59 minutes. Valid date entries are 1-12 months, 1-31 days.
Setting Up a Partition
Partitions are added or removed from the system by applying or removing a partition mask
via Installer Programming section [200]. The number of available partitions depends on
the alarm panel model.
Bell/Siren Operation
Each partition must have a siren. The system siren connected to the bell output of the
alarm controller can be mounted in a central location within hearing range of all partitions.
Each partition can also have wireless sirens activated only on the assigned partition.
Keypad Partition Setup
Keypads can be configured to control an individual partition or all partitions.
1.
Enter Installer Programming [*][8][installer code].
2.
Select [861]-[876] to program keypads 1-16.
• Press [000] for partition assignment.
• For global operation, key in 00.
• To assign a keypad to a partition, key in 01-08 for partition 1-8.
3.
Press the [#] key twice to exit programming.
Continue this procedure at each keypad until all have been programmed.
Users are assigned partition access rights via the [*][5] menu.
Assign sirens to partitions:
[804]>[000]>[551]-[556]>[000]
Set up partition account codes:
[310]>[001]-[008]
Set up partition timers:
•
Entry/exit delay, settle delay – [005]>[001]-[008]
•
Automatic arming/disarming schedule – [151]-[158]>[001]/[002]
•
Auto disarming holiday schedule – [151]-[158]>[003]
•
No activity arming – [151]-[158]>[006]
•
Automatic clock adjust – [005]>[000], option 6
•
Delay between dialing attempts – [377]>[012]
Module
HS2016
HS2032
HS2064
HS2128
HSM2108 8 Zone expander
1
3
7
15
HSM2208 8 Output expander
2
4
8
16
Wireless Keypad:
HS2LCDRF(P)4
HS2ICNRF(P)4
HS2LCDWF(P)(V)4
8
8
8
16
HSM2300 Power Supply 1A
3
3
3
4
HSM2204 4 High Current Output
1
1
3
4
HSM2HOSTx Transceiver
1
1
1
1
PC5950 Audio Verification
(not UL evaluated)
1
1
1
1
Method
Description
Procedure
Template
programming
Use pre-defined templates to
quickly apply basic pro-
gramming and to set up DLS
downloading.
Press [899] at the “Enter Section”
screen.
See the PowerSeries Neo Refer-
ence Manual for details.
DLS
programming
Download and apply pro-
gramming using DLS-5™
(v.1.3 or higher) software.
For local DLS, use a PC-Link cable
and laptop with DLS-5 software
installed.
For remote DLS, use a telephone
line, cellular network or the Inter-
net.
Installer
programming
Manually program all alarm
system and device options.
Press [*][8][installer code] while
the system is disarmed.
01 = English
11 = Swedish
21 = Russian
02 = Spanish
12 = Norwegian
22 = Bulgarian
03 = Portuguese
13 = Danish
23 = Latvian
04 = French
14 = Hebrew
24 = Lithuanian
05 = Italian
15 = Greek
25 = Ukrainian
06 = Dutch
16 = Turkish
26 = Slovakian
07 = Polish
18 = Croatian
27 = Serbian
08 = Czech
19 = Hungarian
28 = Estonian
09 = Finnish
20 = Romanian
29 = Slovenian
10 = German