FCC COMPLIANCE STATEMENT

CAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority 
to use this equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the 

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa-

tion. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with 

the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference 

will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, 

which can be deter-mined by turning the equipment off and on, the user is encouraged to try to correct the interference by one 

or more of the following measures:

Re-orient the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/television technician for help.

The user may find the following booklet prepared by the FCC useful: "How to Identify and Resolve Radio/Television Interfer-

ence Problems". This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402, Stock # 004-

000-00345-4.

IMPORTANT INFORMATION

This equipment complies with Part 68 of the FCC Rules. On the side of this equipment is a label that contains, among other 

information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this number 

must be provided to the Telephone Company.

HS2128 Product IdentifierUS: F53AL01BHS2128

REN:0.1B

USOC Jack:RJ-31X

Telephone Connection Requirements 

A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applica-

ble FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is provided with 

this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions 

for details.

Ringer Equivalence Number (REN)

The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a tele-

phone line may result in the devices not ringing in response to an incoming call.

In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be 

connected to a line, as determined by the total RENs, contact the local Telephone Company. For products approved after July 

23, 2001, the REN for this product is part of the product identifier that has the format.

US: AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). For ear-

lier products, the REN is separately shown on the label.

Incidence of Harm

If this equipment HS2016/HS2032/HS2064/HAS2128 causes harm to the telephone network, the telephone company will 

notify you in advance that temporary discontinuance of service may be required. But if advance notice is not practical, the 

Telephone Company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint 

with the FCC if you believe it is necessary.

Changes in Telephone Company Equipment or Facilities

The Telephone Company may make changes in its facilities, equipment, operations or procedures that could affect the opera-

tion of the equipment. If this happens the Telephone Company will provide advance notice in order for you to make necessary 

modifications to maintain uninterrupted service.

Equipment Maintenance Facility

If trouble is experienced with this equipment HS2016/HS2032/HS2064/HAS21284 for repair or warranty information, please 

contact the facility indicated below. If the equipment is causing harm to the telephone network, the Telephone Company may 

request that you disconnect the equipment until the problem is solved. This equipment is of a type that is not intended to be 

repaired by the end user.

DSC c/o APL Logistics, 757 Douglas Hill Rd., Lithia Springs, GA 30122

Additional Information

Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commis-

sion or corporation commission for information.

Alarm dialling equipment must be able to seize the telephone line and place a call in an emergency situation. It must be able to do 

this even if other equipment (telephone, answering system, computer modem, etc.) already has the telephone line in use. To do 

so, alarm dialling equipment must be connected to a properly installed RJ-31X jack that is electrically in series with and ahead of 

all other equipment attached to the same telephone line. Proper installation is depicted in the figure below. If you have any ques-

tions concerning these instructions, you should consult your telephone company or a qualified installer about installing the RJ-

31X jack and alarm dialling equipment for you.

INDUSTRY CANADA STATEMENT

NOTICE:

 This Equipment, HS2016/HS2032/HS2064/HAS2128,

meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration 

number. The abbreviation, IC, before the registration number signifies that registration was performed based on a Declaration 

of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada 

approved the equipment

NOTICE:

 The Ringer Equivalence Number (REN) for this terminal equipment is 0.1. The REN assigned to each terminal 

equipment provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The 

termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the 

Ringer Equivalence Numbers of all devices does not exceed five.

L’indice d’équivalence de la sonnerie

(IES) sert à indiquer le nombre maximal de terminaux qui peuvent être raccordés à une interface téléphonique. La terminaison 

d’une interface peut consister en une combinaison quelconque de dispositifs, à la seule condition que la somme d’indices 

d’équivalence de la sonnerie de tous les dispositifs n’excède pas 5.

Certification Number:

IC: 160A-HS2128

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

UL/ULC Installations

This product has been tested and found in compliance with the following standards:

UL1610 Central-Station Burglar-Alarm Units

UL365 Police Station Connected Burglar Alarm Units and Systems

UL1023 Household Burglar-Alarm System Units

UL985 Household Fire Warning System Units

UL1635 Digital Alarm Communicator System Units

UL1637 Home Health Care Signaling Equipment 

ULC-S304-06Signal Receiving Centre & Premise Burglar Alarm Control Units

ULC-S559-04Equipment for Fire Signal Receiving Centers and Systems

ULC-S545-02 Residential Fire Warning System Control Units

ORD-C1023-1974 Household Burglar-Alarm System Units

This product has also been tested and found in compliance with the ANSI/SIA CP-01-2010 Control Panel Standard – Features 

for False Alarm Reduction.

This product is UL/ULC listed under the following categories: 

AMCX/AMCXCCentral Stations Alarm Units

APAWPolice-station-connected Alarm Units

DAYRCCentral Station Fire Alarm System Units

UTOU/UTOUC Control Units and Accessories, Household System Type

NBSX/NBSXC Household Burglar Alarm System Units

AMTB Control Panels, SIA False Alarm Reduction

The product is labeled with the UL and ULC listing marks along with the SIA CP-01 compliance statement (Also Classified 

in accordance with SIA-CP-01 Standard) as proof of compliance with the above mentioned standards. For further information 

on this product’s listings please also refer to the official listing guides published at the UL web site (www.ul.com) under 

Online Directions Section.

UL/ULC Residential Fire and Burglary Installations:

For ULC Installations refer to the Standard for the Installation of Residential Fire Warning Systems, CAN/ULC-S540.

All burglary-type zones shall be configured with SEOL or DEOL configuration 

(refer to section [002], bit 10 or 11 shall be ON)

Use at least one PG9926 or PG9916 Smoke Detector for Fire Installations (section [001], fire zone shall be 

programmed as type 025)

The entry delay shall not exceed 45 seconds (refer to section [005])

The exit delay shall not exceed 60 seconds (refer to section [005])

The minimum Bell Time-out is 4 minutes (refer to section [005])

Note:

 

For ULC Residential Fire Installations the minimum Bell Time-out is 5 minutes

For UL Home Health Care Installations the minimum Bell Time-out is 5 min.

For UL Commercial Burglary Installations minimum Bell Time-out is 15 min.

Temporal Three Fire Signal shall be enabled (section [013], opt.8 ON)

Arm/Disarm Bell Squawk shall be enabled when using wireless key PG4939, PG4929, PG4949 (section [014], 

option 1 shall be ON)

A code shall be required for bypassing (section [023], option 4 shall be ON)

Trouble beeps shall be enabled (section [022], option 7 shall be ON)

AC trouble indication LED shall be enabled (Keypad Programming, section [022], options 5 and 6 shall be ON)

DACT Communicator shall be enabled for Supervising Station Monitoring (section [380], option 1 shall be ON) 

Note:

 

The DACT communicator for this product has no line security.

Telephone Line Monitoring (TLM) shall be enabled (section [015], option 7 shall be ON)

Note:

 

This product shall be programmed to perform 5 (min.) to 10 (max.) attempts for communication of an event to 

the supervising station. If unsuccessful, a Fail To Communicate (FTC) trouble is generated.

 

Test transmission cycle shall be set for monthly transmission (refer to section [351]) 

Note:

 

For ULC Residential/Commercial installations set for daily test transmission

Wireless Supervision window shall be set to 4 hours for Fire Installations (Wireless Programming, section 

[804]>[802] shall be programmed with the value 16)

Note: The wireless devices are not suitable for ULC Commercial installations

Wireless Supervision window shall be set to 4 hours for Burglary Installations only (Wireless Programming, 

section [804]>[802] shall be programmed with the value 96)

RF Jam detection shall be enabled (refer to Wireless Programming (section [804][801], option 00 shall be 

OFF)

New Alarms will Disconnect 2-way Audio (section [022], opt 6 OFF)

For UL/ULC Commercial Burg all units are to be installed in protected premise. UL Central Station and Police Connect with 

Standard or Encrypted Line Security Service

The installation must use the Models TL2803G(R) IP/3G Interface, 3G2080(R) 3G Interface or TL280(R) IP 

Interface, which communicates over Cellular Data Network or an Ethernet network 10/100BaseT to the com-

patible Sur-Gard System I/II/III/IV receiver.

Polling time shall be 200 seconds and compromise detection time shall be 6 min.

Central station and Police station connect encrypted line security: Bell test for police station connect shall be 

enabled (programming section [014] option 1 and 3). For Encrypted line security applications, the Models 

TL2803G(R) IP/3G Interface, 3G2080(R) 3G Interface or TL280(R) IP Interface shall have the Encryption 

Key enabled (AES 128-bit encryption algorithm is validated under NIST Certificate No.2645).

Wireless Supervision window shall be enabled (refer to Wireless Programming, sections [804]>[802])

UL Local Mercantile, Central Station and Police Connect with No Line Security Service. For dual line signaling the primary 

line could be the onboard integral DACT. the secondary line should be Cell or IP and shall be encrypted.

The installation shall use a Bell which is UL Listed for Mercantile local alarms. An example of a UL Listed 

bell that can be used is Amseco Model MBL10B bell with Model AB-12 bell housing. Connections from the 

control unit to the bell shall be made in conduit. (Optional for central Station)

The bell timeout shall be programmed for 15 minutes minimum

At least one system remote keypad with tamper switch shall be employed

The integral DACT shall be enabled and shall be programmed to provide a low battery transmission (Not 

required for local installation)

The control panel shall be in the attack resistant enclosure. The separately listed CMC-1 or PC4050CAR attack 

resistant enclosure shall be employed

The maximum entry delay time shall not exceed 45s as a result of the attack test. The maximum exit delay time 

shall not exceed 45 seconds.

A tamper switch shall be used to protect the enclosure cover of the control unit. A tamper switch shall also be 

used on the keypad rear to detect removal from the wall.

24 h check in transmission shall be enabled

Open/Closing acknowledgement enabled.(Not Police Station, 

Local

)

The Installation shall use the internal dialer (DACT) alone or in conjunction with Models TL2803G(R) IP/3G 

Interface, 3G2080(R) 3G Interface or TL280(R) IP Interface, which communicates over Cellular Data Net-

work or an Ethernet network 10/100BaseT to the compatible Sur-Gard System I/II/III/IV receiver.

UL Home Health Care Signaling Equipment

There must be at least two keypads, one of either one of the compatible keypads models HS2LED, 

HS2LCD(P), HS2ICN(P), HS2LCDRF(P)9, HS2ICNRF(P)9

Each system shall be programmed to activate an audible Trouble signal within 90 seconds upon loss of micro-

processor memory

ULC Central Station Fire and Burglary Monitoring Installations

For installation requirements, levels of security, communication modules and configurations (Refer to the ULC 

Installation Information Sheet, DSC #29002157)

Use a CSA/cUL approved transformer,

 model Standex FTC3716

 (hardwired connections required for Fire 

Monitoring)

All tamper circuits may be connected to the same zone. The separately listed PC4050CR enclosure shall be 

employed with ULC-LA AC Indicator Assembly

WIRED CARBON MONOXIDE DETECTOR

1. When DSC wired carbon monoxide detector is used the alarm signal consists of a 4-pulse temporal pattern annunciated at 

the control unit and CO detector. At least one UL Listed audible device rated to operate over the voltage range of 10.4 to 12.5 

V DC and rated 85 dB minimum is to be used.

2.Off-premises CO signal is sent to the central station.

3.The control unit is not Listed to UL 2075.

4. Examples of Wired CO that may be used Quantum Model 12-24SIR, Napco Model FW-C012 or FW-CO1224

Programming

The notes in the programming sections of the PowerSeries Neo Reference Manual describing the system configurations for 

UL/ULC listed installations shall be implemented.

Control of the Protected Premises

In order to have a UL certificated system, the protected area is to be under the responsibility of one ownership and management 

(i.e., one business under one name). This may be a group of buildings attached or unattached with different addresses but under 

the responsibility of someone having mutual interest. The person of mutual interest is not the alarm-installing company.

Note:

 This does not apply to strip mall applications where each independent business must have their own separate alarm system.

e.g.,1: a commercial partitioned system that has an office and a warehouse area in a building where each area can be armed or 

disarmed independently. 

e.g.,2: a residential system partitioned so that the garage area is armed separately from the house. 

Each of the above examples is under the sole responsibility of a single owner. The bell and DACT power supply must be in a pro-

tected area including partitioned systems. The bell and DACT power supply must be located where it can be heard by the person 

or persons responsible for maintaining the security system during the daily arming cycle. 

Bell Location

The alarm sounding device (bell) shall be located where it can be heard by the person operating the security system during the 

daily arming and disarming cycle.

Protection of the Control Unit

The local control unit and the local power supply must be protected in one of the following ways:

The control unit and audible alarm device must be in a protected area which is armed 24 hours a day.

Each partition must arm the area protecting the control unit and the audible alarm device power supply. This 

may require duplicate protection armed by each partition. Access to this protected area, without causing and 

alarm, will require that all partitions be disarmed.

In all cases described above, the protected area for the control unit must be programmed as not-bypassable.

Casual Users

The installer should caution the user(s) not to give system information (e.g., codes, bypass methods, etc.) to casual users 

(baby-sitters or service people). Only the One-Time Use codes shall be given to casual users.

User Information

The installer should advise the users and note in the User’s Manual:

Service organization name and telephone number

The programmed exit time

The programmed entry time

Test system weekly

The installer code cannot arm or disarm the system

firealarmresources.com

Содержание DSC PowerSeries neo

Страница 1: ...t Test the panel completely to ensure that all features and functions operate as programmed 901 Walk Test 904 000 Wireless Placement Test Modules Wireless keypads HS2LCDWFxUL HS2LCDWFPxUL HS2LCDWFPVxU...

Страница 2: ...lephone connection e Do not route any wiring over circuit boards f The installer must ensure that a readily accessible disconnect device is incorporated into the building for permanently connected ins...

Страница 3: ...sistors When double end of line DEOL resistors are installed at the end of a zone loop the sec ond resistor enables the panel to determine if the zone is in alarm tampered or faulted Diagram 1 4 DEOL...

Страница 4: ...quired Programming Once basic installation of the alarm panel is complete the following general configuration options can be set 000 Language Selection LCD keypads only Use this section to set the lan...

Страница 5: ...ication 9 Normally Closed EOL 10 Single EOL 11 Double EOL 12 Fast Normal Loop Response Trouble Detailed Trouble 01 Service Required 01 Bell circuit 02 RF jam detected 03 Aux supply trouble 04 Time and...

Страница 6: ...on PGM2 being used as a 2 wire smoke detector input This trouble is generated by a short on hardwired zones when DEOL is used Ensure a 2 2K EOL resistor is connected red red red Remove wire leads from...

Страница 7: ...led in the same enclosure and configured as primary or back up with AES 128 bit encryption Compliant with EN50136 1 1 EN50136 2 1 ATS2 requirements Trouble 10 Module Tamper Press 10 to determine speci...

Страница 8: ...03 Maintenance Code AAAA00 PGM Programming 007 PGM Programming 000 Main Bell Partition Assignment 1 Partition 1 2 Partition 2 3 Partition 3 4 Partition 4 5 Partition 5 6 Partition 6 7 Partition 7 8 Pa...

Страница 9: ...Thursday Friday Saturday 003 Auto Disarming Holiday Schedule Holiday 1 Holiday 2 Holiday 3 Holiday 4 004 Auto Arming Pre Alert 004 005 Auto Arming Postpone Timer 000 006 No Activity Arming Timer 000...

Страница 10: ...g 4 Pulse Dial After 5th Attempt 5 Parallel Communications 6 Alternate Dial 7 Reduced Dialing Attempts 8 Activity Delinquency 381 Communicator Option 2 1 Keypad Ringback 2 Bell Ringback 4 Closing Conf...

Страница 11: ...may not remove any proprietary notices marks or labels from the Software Product You shall institute reasonable measures to ensure compliance with the terms and conditions of this EULA b Separation of...

Страница 12: ...80 017 081 018 082 019 083 020 084 021 085 022 086 023 087 024 088 025 089 026 090 027 091 028 092 029 093 030 094 031 095 032 096 033 097 034 098 035 099 036 100 037 101 038 102 039 103 040 104 041 1...

Страница 13: ...Wireless Device Record Installer Defined Access Codes System Account Code Module Type Slot Serial Number Module Type Slot Serial Number Device Type Zone Serial Number Device Type Zone Serial Number 0...

Страница 14: ...Fire Installations section 001 fire zone shall be programmed as type 025 The entry delay shall not exceed 45 seconds refer to section 005 The exit delay shall not exceed 60 seconds refer to section 00...

Страница 15: ...s of time Also an intruder may cut the telephone line or defeat its operation by more sophisticated means which may be difficult to detect Insufficient Time There may be circumstances when the system...

Страница 16: ...entry and exit delays and bell time out for the system Note Combined entry delay and communications delay abort window shall not exceed 60s Range 30 sec to 4 min Default 30 sec Required programmable A...

Отзывы: