- 12 -
Installation
The TL8803GI-IL2 has two covered access ports on the top of the enclosure. Remove the plastic tab covering
the desired port and either mount the antenna on the enclosure or use the opening to pass through the antenna
cable.
Note:
Due to the curvature of the enclosure, the plastic port covers are NOT interchangeable. Ensure that any
unused ports are covered with their original plastic tab.
Warning
: The external antenna must be installed in a manner to prevent end users from accessing any con-
ductive part of the anntena or antenna cable (i.e., recessed mounting or equivalent).
6: Power up
Connect panel battery and AC power. Once powered, view key items on the LCD. Ensure that the module has
been fully connected to the alarm panel via quad cable as shown in wiring diagram.
Step 3: Verify installer code to activate Alarm.com module
Alarms and other signals will not be sent to Alarm.com until the installer code is verified. To activate the
account, perform the following steps:
1. Connect the Alarm.com module to the panel. Ensure [382] option 5 is ON.
2. Press [*][8] to enter Installer Programming.
3. Enter the installer code.
4. Press [#] to exit Installer Programming.
To remotely activate a system that is already signaling, do the following steps:
1. Go to www.alarm.com/dealer.
2. Go to the customer's account.
3. Select the error message at the top of the page.
4. Enter the installer code.
Step 4: Perform dual-path test (module registration)
To initiate module communication with Alarm.com and the cellular network for the first time, perform a
“Dual-Path phone test”. Note that the test can also be used at any time by the installer to force communication
with Alarm.com. To test the cellular path, press and hold [3] for two seconds. To test the broadband path,
press and hold [4] for two seconds. A Dual-Path test can also be completed through the Interactive Services
menu. To perform the Dual-Path test, press [*][6] followed by the master code and [04].
The panel indicates when the test has completed by activating the siren output on medium volume for 2 seconds
followed by full volume for 2 seconds. However, if the test was initiated via the [3] or [4] key, or through the
Interactive Services menu, the siren will not sound. All display lights and LCD pixels turn on. This indicates
that Alarm.com has received and acknowledged the signal. This does not guarantee that the signal went
through to a central station; it confirms that Alarm.com’s Network Operations Center received the signal. The
central station should be contacted directly to verify that the signal was received on the correct account and
that the central station routing settings have been set up correctly. If the signal does not go through to the cent-
ral station, the panel displays a “Failure to Communicate” message. Double check the account’s central station
Forwarding Settings on Alarm.com and contact technical support if the trouble persists.
Step 5: Allow module to auto-program
After a successful dual-path test, wait 2 minutes for the module to automatically program and initialize before
entering the Installer Programming menus. Entering Installer Programming during module initialization will
Содержание DSC TL8803GI-IL2
Страница 27: ...TL8803GI IL2...
Страница 29: ...29 49 51 51...
Страница 30: ...30...
Страница 31: ...31...
Страница 35: ...l HSPA 5 2 HSPA l TL8803GI IL2 l TL8803GI IL2 l l l l 16 HSPA TL8803GI IL2 1 1 2 3 RS422 Ethernet 2 35...
Страница 37: ...3 HSPA 4 HSPA A PCLink2 B C Ethernet D 100 30 E PCL 422 PCLink F HSPA HSM2204 2300 37...
Страница 43: ...TL8803GI IL2 Alarm com 18 Alarm com 43...
Страница 48: ...TL8803GI Alarm com 5 2 3 5 13 31 123 _ _ 13 l l l l DSC Alarm com HSPA www alarm com l Alarm com l l HSPA 48...
Страница 50: ...HSPA SN SIM Z Wave 1 Z Wave 1 Z Wave 1 Z Wave 1 Z Wave 1 1 Alarm com Z Wave 50...
Страница 53: ...2019 Tyco 1 800 387 3630 905 760 3000 www dsc com Tyco Tyco 29010718R002...