1: Connect data bus
The maximum cable length permitted for the data bus is 100ft/30m.
l
Connect the
RX+
terminal on the TL8803GI-IL2 to the
TX+
terminal on the PCL-422
l
Connect the
RX-
terminal on the TL8803GI-IL2 to the
TX-
terminal on the PCL-422
l
Connect the
TX-
terminal on the TL8803GI-IL2 to the
RX-
terminal on the PCL-422
l
Connect the
TX+
terminal on the TL8803GI-IL2 to the
RX+
terminal on the PCL-422
2: Connect power
The maximum cable length permitted for the power connection is 100ft/30m.
l
Connect the
GND
terminal on the TL8803GI-IL2 to the
GND
terminal on the PCL-422
l
Connect the
+12V
terminal on the TL8803GI-IL2 to the
+12V
terminal on the PCL-422
3: Connect the PC-Link cable
Note:
To ensure correct orientation, refer to items A and D in the wiring diagrams for the proper position of
the red wire on the PC-link cable.
l
Connect one end of the supplied PC-Link cable to the PC-Link header on the PCL-422
l
Connect the other end of the PC-Link cable to the PC-LINK_2 header on the alarm panel
4: Connect Ethernet (optional)
Note:
Refer to item C in the wiring diagram for the correct placement of the Ethernet cable.
A Category 5 (CAT 5) Ethernet cable must be run from a source with Internet connectivity to the com-
municator module, inside the TL8803GI-IL2. The communicator end of the cable must be terminated with an
RJ45 plug.
l
Connect one end of the Ethernet cable to the Ethernet port on the communicator
l
Connect the other end of the Ethernet cable to the Ethernet port on the router and verify that the link
status LED is on.
All requirements for installation of CAT5 Ethernet cable must be observed for correct operation of the
commmunicator, including but not limited to the following requirements:
l
Do NOT strip off cable sheathing more than required for proper termination.
l
Do NOT kink or knot the cable.
l
Do NOT crush the cable with cable ties.
l
Do NOT untwist CAT5 pairs more than 1/2 inch (1.2 centimeters).
l
Do NOT splice the cable.
l
Do NOT bend the cable at right angles or make any other sharp bends.
Notes:
l
CAT5 specification requires that any cable bend must have a minimum 2 inches (5 centimeters) bend
radius. The maximum lenght of CAT5 cable is 328 feet (100 meters).
l
Before leaving the premises, the Ethernet communication lines must first be connected to an approved
(acceptable to local authorities) type NID. All wiring must be performed according to the local electrical
codes.
5: Connect external antenna (optional)
Upgraded antennas are available for the TL8803GI-IL2 if there is inadequate cellular reception at the pre-
ferred mounting location. Contact DSC technical support for antenna options.
- 11 -
Installation
Содержание DSC TL8803GI-IL2
Страница 27: ...TL8803GI IL2...
Страница 29: ...29 49 51 51...
Страница 30: ...30...
Страница 31: ...31...
Страница 35: ...l HSPA 5 2 HSPA l TL8803GI IL2 l TL8803GI IL2 l l l l 16 HSPA TL8803GI IL2 1 1 2 3 RS422 Ethernet 2 35...
Страница 37: ...3 HSPA 4 HSPA A PCLink2 B C Ethernet D 100 30 E PCL 422 PCLink F HSPA HSM2204 2300 37...
Страница 43: ...TL8803GI IL2 Alarm com 18 Alarm com 43...
Страница 48: ...TL8803GI Alarm com 5 2 3 5 13 31 123 _ _ 13 l l l l DSC Alarm com HSPA www alarm com l Alarm com l l HSPA 48...
Страница 50: ...HSPA SN SIM Z Wave 1 Z Wave 1 Z Wave 1 Z Wave 1 Z Wave 1 1 Alarm com Z Wave 50...
Страница 53: ...2019 Tyco 1 800 387 3630 905 760 3000 www dsc com Tyco Tyco 29010718R002...