background image

 

 

 

 

Wire and Harnessing Products

 

Engineering Specification 
 

 

 No: 

ES 61402

  

 Rev: 

 

Date:  July 9, 1991 

 

Page:  1 of 16 

 

If this document is printed it becomes uncontrolled.  Check for the latest revision.

 

 
 
 
 
 
 
 
 
 

RAYCHEM 

 

INTERCONNECTION SYSTEMS DIVISION 

 

ENGINEERING STANDARD 

 

ES 61402 

 
 
 

OPERATING AND MAINTENANCE MANUAL 

 

WAFFLE IRON II HEATING TOOL 

 
 

 

Содержание CE-1404200

Страница 1: ...ES 61402 Rev D Date July 9 1991 Page 1 of 16 If this document is printed it becomes uncontrolled Check for the latest revision RAYCHEM INTERCONNECTION SYSTEMS DIVISION ENGINEERING STANDARD ES 61402 OP...

Страница 2: ...ducts Engineering Specification No ES 61402 Rev D Date July 9 1991 Page 2 of 16 If this document is printed it becomes uncontrolled Check for the latest revision OPERATING AND MAINTENANCE MANUAL WAFFL...

Страница 3: ...WARNING Do not touch infrared lamps They may be hot and can cause burns WARNING In keeping with good industrial hygienic practice adequate ventilation must be maintained whenever plastic materials ar...

Страница 4: ...cable CTM transitions for splicing flat conductor cable to round wire MTC50 and MTC100 connector wafers for flat conductor cable and SEM connector wafers for flat conductor cable The part to be termin...

Страница 5: ...ime period selected After the timed heating period the heat lamps and HEATING indicator light go out the COOLING indicator light illuminates and the blower comes on to cool the platens The cooling cyc...

Страница 6: ...0 120 V 100 120 VAC 50 60 Hz 20 A Model CE 1404300 240 V 200 240 VAC 50 60 Hz 10 A Overall Cycle Time 3 4 Minutes Temperature Per TEMP control dial Setting 0 through 9 Set Point Range Time at Temperat...

Страница 7: ...installation instructions Step 2 Before installation or after cleaning spray or wipe platens with light coat of release agent such as Miller Stephenson MS 122 or Axel MoldWiz o Coat only the side of t...

Страница 8: ...r the latest revision Step 5 Remove install platens as required o Platens are locked into heat sinks by a spring loaded retainer o Identification markings face the operator o Top platen has one keying...

Страница 9: ...tive Step 3 Press the START button to initiate a heating cycle to warm the tool and verify its operation o The TEMP and TIME controls can be at any setting for this cycle o The green READY ERROR light...

Страница 10: ...3 Load the assembly to be terminated onto the lower platen of the heating tool o Position CTMs so that the top surface faces upward and the CTM is centered in the platen o Position MTC and SEM connect...

Страница 11: ...flash until the heat sink is closed and the START button is pressed Step 8 Allow the termination cycle to continue until the green READY ERROR light comes on o After the heating portion of the cycle i...

Страница 12: ...gital thermometer with peak hold feature or strip chart recorder must be compatible with type K thermocouple o Stop watch 4 4 Test Procedure 1 Install test platen o For early model Waffle Iron II s wi...

Страница 13: ...uirements in the temperature table below The maximum temperature reached during the 10 second window must fall within the applicable range from the temperature table IMPORTANT A numerical correction f...

Страница 14: ...ty using a soft cloth or tissue moistened with trichloroethane or isopropyl alcohol Do not touch lamps directly with fingers 5 2 Preventing Parts From Sticking Before installation or after cleaning sp...

Страница 15: ...ller fault Contact Raychem field service Flashing green Upper heat sink not Close and latch upper READY ERROR closed and latched heat sink light Operator error Previous termination Remove previous ter...

Страница 16: ...t becomes uncontrolled Check for the latest revision 5 5 Replacement Parts List DESCRIPTION PART NUMBER Infrared lamp top or bottom 966723 Reflector top or bottom 977842 Latch stud for heat sink 96624...