Tomcat i915 S5120
Chapter 4: SATA/RAID Setup (for SATA RAID model)
4-21
http://www.tyan.com
6. Power off your system.
7. Remove the failed drive and replace it with a new drive of the same or larger size.
8. Power on your system and enter the FastBuild Utility.
9. Press 5 to select the Rebuild Array option. The following screen will appear.
10. Highlight the array whose Status is Critical and press Enter. The following screen appears.
11. Under Select Drive for Rebuild, press the arrow keys to highlight the replacement drive.
12. Press Enter and confirm that the data will be copied onto the selected drive.
Data from the original mirror drive will overwrite any existing data on the replacement
drive. A progress bar will appear as below.
When the
Array was recovered...
message appears, the array is ready for use.
13. Press Esc twice to exit FastBuild and allow your system to finish booting.