Cold climate installation
recommendation: When installing this
unit against a non-insulated exterior
wall or chase, it is mandatory that the
outer walls be insulated to conform to
applicable insulation codes.
Voltage:
120VAC, 60 Hz
Total Amps:
12.5 Amps
Watts:
1500 Watts
ELECTRICAL SPECIFICATIONS
A 15 AMP, 120 Volt, 60 Hz circuit with a properly
grounded outlet is required. Preferably, the fireplace
will be on a dedicated circuit as other appliances on
the same circuit may cause the circuit breaker to trip
or the fuse to blow when the heater is in operation.
The unit comes standard with 6’ (1828 mm) three wire
cord, exiting from the rear of the fireplace. Plan the
installation to avoid the use of an extension cord. If an
extension cord must be used, it must be a minimum
E L E C T R I C A L C O N N E C T I O N
When choosing a location for your new fireplace,
ensure that the general instructions are followed.
Also, for best effect, install the fireplace out of direct
sunlight.
POSITIONING/LOCATING YOUR
ELECTRIC FIREPLACE
C L E A R A N C E T O
C O M B U S T I B L E S
Keep electrical cords, drapery, furniture and other
combustibles at least 3 feet(0.9M) from the front of
the heater and away from the sides.
TROUBLE SHOOTING GUIDE
PROBLEM
SOLUTION
1. No power, switches do not light up
1a. Check that unit is plugged into a standard 120V outlet
2. Switches light up, but no flame effect
2a. Remove front kick plate and check for any broken light
bulbs or loose light bulbs
3. Down lights do not light up
3a. Remove front glass top bracket. Carefully lift glass out
of track. Check that both light bulbs inside the top of
the unit are not broken or loose
4. Logs Glow, flame effect does not work
4a. Open back of unit. Check to see if “spinner” is correctly
mounted at to the rear of unit
4b. Check to see if spinning motor is functioning.
If not, call customer service
5. Flame effect operates, but heater does not
5a. Check that heater switch is in “on”
blow warm air
position. Switch should light up.
5b. Make certain that thermostat is turned toward the
“HI” position
14 AWG, three wire with grounding type plug connec-
tor and rated not less than 1875 Watts. The cord shall
not be more than 20 feet in length.
C L E A N I N G T R I M
Clean the metal trim using a soft cloth, slightly
dampened with a citrus oil based product and buff
with a clean soft cloth. DO NOT use brass polish or
household cleaners as these products will damage the
metal trim. Citrus oil based products can be obtained
at supermarkets or hardware stores.
E-4