LP GAS HOOK-UP
–
P
INNACLE
G
AS
G
RILL
Install the factory-supplied hose and regulator assembly as shown. Connect the 3/8-flare end of the hose
to the grill coupling using a 3/4 open wrench. Do not apply pipe sealant to the 3/8-flare connection. Connect the
regulator to the LP cylinder. Do not use a wrench but hand tighten the regulator. Check for leaks using soapy
water solution.
Note:
An enclosure for LP gas cylinder must be vented on the level of the cylinder valve and at floor
level. The effectiveness of the opening(s) for purposes of ventilation shall be determined with the LP gas
supply cylinder in place. This shall be accomplished by one of the following:
a.
One side of the enclosure shall be fully open; or
b.
For an enclosure having four sides, a top and a bottom:
1.
At least two ventilation openings at cylinder valve level shall be provided in the sidewall,
equally sized, spaced at 180 degrees (3.14 rad), and unobstructed. Each opening shall have a
total free area of not less than 1/2 square inch per pound (7.1 cm
2
/kg) of stored fuel capacity
and not less than a total free area of 10 square inches (64.5 cm
2
).
Ventilation opening(s) shall be provided at floor level and shall have a total free area of not less
than 1/2 square inch per pound (7.1 cm2/kg) of stored fuel capacity and not less than a total free area of
10 square inches (64.5 cm2). If ventilation openings at floor level are in a sidewall, there shall be at least
two openings. The bottom of the openings shall be at floor level and the upper edge no more than 5
inches (127 mm) above the floor. The openings shall be equally sized, spaced at 180 degrees (3.14 rad)
and unobstructed.
5
4" MINIMUM CLEARANCE
TO ALLOW LID TO
FULLY OPEN