CLEARANCE TO COMBUSTIBLE CONSTRUCTION
A minimum clearance of
12”
from the sides and
back of the grill to adjacent vertical combustible construction must be maintained.
CLEARANCE TO
NONCOMBUSTIBLE CONSTRUCTION
A minimum clearance of 4” from the back of the grill above
cooking surface to non-combustible construction is required to allow the grill hood to open completely. A
minimum of 6” clearance to the sides of the grill above cooking surface to non-combustible construction is
recommended to provide space for the rotisserie motor and the skewer handle. The grill can be installed directly
next to non-combustible construction below the cooking surface.
This gas appliance is design and certified for outdoor use
only. Do not operate the grill inside a building, garage,
recreation vehicle or any enclosed area. When choosing
an area, consider exposure to wind, proximity to
traffic paths and length of gas
supply line. Keep gas supply
lines as short as
possible to reduce
pressure drop. Keep
the grill away from
windy area but keep the
grill in a well-ventilated area.
Do not obstruct the flow
of combustion and ventilation
air around the grill.
DO NOT locate
the grill under
overhead
unprotected
combustible
surfaces.
9