Chapter 7 Troubleshooting
- 58 -
* Avoid the water flowing
into the pump well forming a
waterfall and rushing down.
Move the sensor to a place
where air bubbles are not
easy to get in.
* The inlet side of the pump.
*Upstream side of the valve.
High turbidity: Higher than
the turbidity of injected
sewage and returned
sludge.
The sensor installation V
method is changed to Z
method.
Move the sensor to the
smaller part of the pipeline
on the same pipeline.
Move the sensor to other
parts or other pipes.
Try the large sensor option.
Move the sensor to the
straight pipe.
A large amount of scale
deposits inside the old
pipe.
Lining peeling: There is a
gap between the lining and
the pipe.
Thicker lining: Due to the
use of mortar lining, the
thickness is more than
tens of millimeters.
The sensor is installed at
the elbow or tapered pipe.
3
、
The influence of external
noise
Try to shorten the cable
length between the host
and the sensor.
*There is a radio signal
transmitting station nearby.
Содержание MC-SUP2000H
Страница 1: ...Medidor de flujo ultrasónico en líquidos portátil Meacon MC SUP2000H ...
Страница 5: ......
Страница 11: ...Chapter 1 Introduction 6 1 6 Parts Identification 1 6 1 Converter Front view Side view ...
Страница 16: ...Chapter 1 Introduction 11 View and size Small size HS Medium size HM ...
Страница 17: ...Chapter 1 Introduction 12 High temp Small size HS HT ...
Страница 18: ...Chapter 1 Introduction 13 High temp Medium size HM HT Extension bracket ...
Страница 69: ......