![Tweco ULTRAFEED VAF-4 Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/tweco/ultrafeed-vaf-4/ultrafeed-vaf-4_service-manual_1183842079.webp)
ULTRAFEED VAF-4
Manual 0-5332
TROUBLESHOOTING 5-11
5.08 Check Main ON / OFF Switch (Main Power OFF)
Art # A-12018_AB
TP16
TP15
TP18
TP17
Figure 5-3 Main ON / OFF Switch
Power Switch Testing
Multimeter Lead Placement
Diode Voltage
Switch ON
Positive meter lead to TP 15
Negative meter lead to TP 16
0 to 1
W
Switch ON
Positive meter lead to TP 17
Negative meter lead to TP 18
0 to 1
W
Switch OFF
Positive meter lead to TP 15
Negative meter lead to TP 16
> 1k
W
Switch OFF
Positive meter lead to TP 17
Negative meter lead to TP 18
> 1k
W
Table 5-6 Power Switch, Multimeter set to measure ohms (
W
)