Problem

Possible Cause

Corrective Action

Wire  feed  inconsistent  or  not 
smooth.

1.  Loose drive Rollers on feeder.
2.  Dirty or plugged conduit.
3.  Conduit pulled back from diffuser. 

4.  Sharp bends or kinks in conduit.
5.  Machine improperly adjusted. 

6.  Spatter buildup on end of contact tip.
7.  Loose contact tip or diffuser. 

8.  Excessively worn contact tip.
9.  Loose ground cable or ground clamp.

1.  Tighten drive rollers.
2.  Replace conduit. 
3.  Reposition conduit and tighten front 

screw.

4.  Remove and replace conduit.
5.  Reset machine per machine and wire 

manufacturers’ recommendations.

6.  Clean or replace contact tip.
7.  Tighten contact tip and diffuser plier 

tight.

8.  Replace contact tip.
9.  Tighten or replace as required.

Torch  and  cable  assembly  is 
running hot.

1.  Loose power connection. 

2.  Loose or undersize ground cable or 

ground clamp.

3.  Conductor tube not tight in torch block. 

4.  Loose contact tip or diffuser.
5.  Operating torch and cable assembly 

above recommended amperage rating.

6.  Power cable assembly damaged.
7.  Restricted water flow (only QRW and 

QRWA series torch).

1.  Inspect complete torch and cable for 

loose connections and tighten.

2.  Tighten or replace as required. 

3.  Tighten stainless setscrew in torch 

block.

4.  Tighten contact tip and diffuser.
5.  Readjust machine to correct setting for 

size of torch being used.

6.  Inspect and replace accordingly.
7.  Inspect water lines for any excessive 

bends.

Robot will not start.

1.  Deflection mount not at “home” 

position.

2.  Check E-stop cable connection.

1.  Check to ensure the mount arm and 

mount location.

2.  Check E-stop cable connection.

Porous weld.

1.  Poor or improper gas flow. 

 

2.  Moisture from torch/conductor tube. 

 

3.  Dirty or contaminated wire.
4.  Base metal contamination.

1.  Check gas flow out of conductor tube 

nozzle.  Check for leaks or restrictions 
in gas hoses and connections.

2.  Check O-rings on conductor tube and 

torch block.  Check the torch block for 
any scarring, gouges to the surface.

3.  Change wire.
4.  Replace base metal.

Содержание Light Weight

Страница 1: ...E GTAW SMAW INVERTER CC DC 115 V 230 V Version No AA 01 Issue Date June 30 2006 Manual No SM QRLTORCH 06 06 qUICK rOBOTICS tORCH installation Guide and replacement Parts Manual light Weight English Fr...

Страница 2: ...oid potential hazards that may exist when working with this product YOU ARE IN GOOD COMPANY The Brand of Choice for Contractors and Fabricators Worldwide Tweco Robotics is a Global Brand of Arc Weldin...

Страница 3: ...Road Denton TX 76208 940 566 2000 www tweco com Copyright 2006 by Thermadyne Industries Inc All rights reserved Reproduction of this work in whole or in part without written permission of the publish...

Страница 4: ...1 How to Use this Manual 2 4 2 02 Receipt of Equipment 2 4 2 03 Introduction 2 4 2 04 Standard Features 2 4 SECTION 3 Installation and Disassembly 3 6 3 01 Installation 3 6 3 02 Disassembly 3 8 SECTIO...

Страница 5: ...PMENT WITH PROTECTIVE INSULATORS OR COVERS REMOVED SERVICE OR REPAIR TO EQUIPMENTMUSTBEDONEBYAQUALIFIEDREPAIR TECHNICIAN OR TRAINED PERSONNEL ONLY 1 Do not touch live electrical parts 2 Do not touch a...

Страница 6: ...toxic gas Phosgene when exposed to ultraviolet radiation from an electric arc All solvents degreasers and potential sources of these vapors must be removed from the work area 15 Fumesproducedbyweldin...

Страница 7: ...ires and explosions Excessive noise can damage your hearing 1 03 Safety and Health NOTICE Be sure to read and fully comprehend the safety instuctions and warnings contained within section 1 of this ma...

Страница 8: ...ess and phone number in your area listed on the inside back cover of this manual Include the Manual number from page i and CD part number 64 2601 2 03 Introduction The new Tweco Robotics Quick Robotic...

Страница 9: ...r Cable This cable enables the connection of the QRLTorch to the RDM 2000 series Tweco Robotics Deflection Mount Stock No 3044 1860 Figure 1 QRL Series Air cooled Assembly INTRODUCTION AND DESCRIPTION...

Страница 10: ...ly Insertthefactorysupplied 5 32 T handleallenwrenchintothelockingscrewandrotate counterclockwise until it stops 5 Insert the conductor tube assembly into the torch block assembly The conductor tube i...

Страница 11: ...illerstylerearconnector plug re install the threaded connector plug nipple This connection should be wrench tight 15 Re insertthefactory supplied5 32 T handleallenwrench into the hole labeled Conduit...

Страница 12: ...duit radius 18 Re install the diffuser tip and nozzle onto the conductor tube assembly 19 Loosen the fixture connection and insert the torch and conductor tube assembly into position The key located o...

Страница 13: ...PIN SOCKET BLUE BLACK BROWN WHITE RED BLACK RECEPTACLE AMP 206705 2 HOUSING AMP 207008 1 E STOP CONNECTOR BLUE BROWN BLACK The QRL torch is furnished with a receptacle housing mounted on the front cas...

Страница 14: ...The torch and conductor tube assemblies have o rings for seals Lubrication of these o rings should be done periodically and periodical inspections should be made to ensure that the o rings do not deg...

Страница 15: ...r tube not tight in torch block 4 Loose contact tip or diffuser 5 Operating torch and cable assembly above recommended amperage rating 6 Power cable assembly damaged 7 Restricted water flow only QRW a...

Страница 16: ...LH 3045 1710 QRl Case 3 QR106 RLS 3045 1341 Conductor Tube Locking Screw Qty 5 4 QTRMS BS 3045 1156 Woodruff Keys Qty 5 5 QRL106S 3045 1347 Conduit Screw 6 QRLRH 3045 1706 QRL Receptacle Housing Assem...

Страница 17: ...5 2110 Tweco Connector Plug Uses R44 series Conduit 18 QTR176LH 2086 2624 Lincoln Connector Plug 2 71 68 83mm OAL EL176LH 2060 2680 Lincoln Connector Plug 3 84 97 54mm OAL 19 350 174PH 2035 2172 Panas...

Страница 18: ...1023 3m 0 9mm 1 2mm 1450 1041 1 2m 035in 045in R45 3545 4 4ft 035in 045in R45WN 3545 8 8ft 0 9mm 1 2mm 1450 1024 1 2m 0 9mm 1 2mm 1450 1042 2 4m 035in 045in R45 3545 8 8ft 035in 045in R45WN 3545 15 1...

Страница 19: ...ng the FRC service repairs on your product All products will be rebuilt and tested following the established test procedures and specifications for the specific product All repairs are done using orig...

Страница 20: ...for service interruption The remedies of the Purchaser set forth herein are exclusive and the liability of THERMADYNE with respect to any contract or anything done in connection therewith such as the...

Страница 21: ...tors Solenoids Fans Electric Motors Coolant Recirculators 1 year 1 year SMAW Stick Welding Equipment Parts Labor Dragster 85 Original Main Power Magnetics 1 year 1 year Original Main Power Rectifiers...

Страница 22: ...Ding Xi Rd Chang Ning District Shanghai PR 200052 Telephone 86 21 6280 1273 Fax 86 21 3226 0955 Thermadyne Asia Sdn Bhd Lot 151 Jalan Industri 3 5A Rawang Integrated Industrial Park Jln Batu Arang 480...

Страница 23: ...World Headquarters Thermadyne Holdings Corporation Suite 300 16052 Swingley Ridge Road St Louis MO 63017 Telephone 636 728 3000 Fascimile 636 728 3010 Email www thermadyne com www tweco com...

Отзывы: