Manual 2003 Rev D p/n 2003
21
05
Installation
MOTOR AND ELECTRICAL
CONNECTIONS
WARNING
!
The motor and connections shall be protected
to assure that product and environmental
condensation does not come in contact with the
electrical connections.
It is the responsibility of the installer to assure
that the motor is in compliance with the latest
edition of IEC 60204-1 and all electrical
connections are performed per IEC 60204-1,
this includes overcurrent protection.
Wire the motor and other electrical devices, such
as solenoid valves and temperature switch, to the
proper voltage and amperage as indicated on the
nameplate of the component being wired. Turn
the booster by hand after wiring is completed to
determine that there are no obstructions and that
the booster turns freely. Then, momentarily start
the booster to check the direction of rotation.
Figure 4-2
shows direction of airflow in relation to
rotor rotation. The airflow direction can be reversed
by reversing the appropriate motor leads.