83
mWing
Cleaning and maintenance
12
Cleaning and maintenance
12.1
Cleaning the pedestrian gate
NOTICE
Aggressive cleaning aids and substances!
Aggressive detergents and consumables may damage or destroy
components, electric cables, or the coating of the pedestrian
gate.
›
Do not use cleaning agents with aggressive ingredients.
Cleaning the pedestrian gate from the outside
1. Switch off power supply and secure against restarting.
2. Pre-clean surfaces with a moist cloth. Never use wet cloth.
3. Clean the surface with a mild household cleaner.
4. Carefully clean areas with persistent dirt with spirit.
5. Dry surfaces with a dry cloth.
12.2
Maintenance schedule
The maintenance plan lists all work required to ensure safe, optimum and
trouble-free operation of the pedestrian gate.
Interval
Work
Personnel
Monthly
Check emergency function.
Operator
Check the swing wings and inlay from the
outside for damage.
Operator
Every 6 months
Check the attachment of the swing wings.
Technician
Check the function of the external residual
current circuit breaker.
Technician
Every 12 months
Check electrical lines for damage.
Technician
Check if all electrical connections are firm.
Technician
Check the fastening of the housing.
Technician
Table 12:
Maintenance schedule