36
Code
Meaning
Range
T Description
SE
Sensitivity of
the Metal
Detector
-100 .. 0..99
C
R
Selection of the Metal Detector Sensitivity :
-100: minimum sensitivity, detection of large metal masses
99: maximum sensitivity, detection of small metal masses
SENT
Sensitivity of
the Metal
Detector
without transit
0…100
C
R
Function available with photocells option only.
Percentage of the sensitivity threshold applied when no transit is in progress.
SN
Serial number -
R Serial number of the equipment.
UP
Selects the
commands
that can be
accessed by
the user
Y,N
C
Command not accessible at user level.
Selects the commands that can be accessed by the user. The command codes will be
displayed followed by an indication in brackets of the current status: (Y) = activated, (N) =
deactivated
sUP
_
*__*
sAC
_
*
(Y)
::
Local programming
The status of each command is changed by pressing the
or
keys. If you
do not wish to change the state of the command you need only press
and the
display will scroll to show the following command. Press the
key to interrupt the
selection procedure
Remote programming
The state of each command is changed by entering the opposite value to the current one to
the right of the # character. If the user does not wish to change the command state, he/she
can simply press ENTER, and the cursor will move on to the following command. Press ‘.’ to
interrupt the selection procedure.
WHO
Who am I?
U S
R Function available in remote mode only.
This function reports the current access level when programming through MDSCOPE utility.
U
user level
S
super-user level
WIE
WiFi Enabling NO, ADHC,
CLNT, AP
C
R
Command available only if a network adapter APSIM with wireless capability is
installed.
NO
the WiFi interface is disabled.
ADHC the WiFi interface is enabled: the unit is set to operate in a ‘ad hoc’ network (only
for service operations).
CLNT the WiFi interface is enabled: the unit is set to operate as a CLIENT and requires an
access point available.
AP
the WiFi interface is enabled: the unit is set to operate as an ACCESS POINT itself.
ZL
Lateral zone
NO, YES
C
R
Function not available in very high sensitivity models.
This parameter enables or disables the horizontal zone alarm indication:
NO (the horizontal zone alarm indication is disabled. The vertical zone indication is supplied
using both exit light bars);
YES (the horizontal zone alarm indication is enabled).