![Turnstiles 02PN20 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/turnstiles/02pn20/02pn20_installation-use-and-maintenance-manual_1182217020.webp)
20
3.3.3
Assembly Procedure of the Column-Shape Version
PSA
pcc
AW1
AW2
K
cf
vc
cbc
vc
cbc
PH
IK
ccp
PC
TX
TX antenna
RX
RX antenna
C1
Crossbar fitted with holes
for mounting the control
unit
vt
crossbar fixing screw
CU
Control
unit
PSA
AC/DC power supply
adapter
IK
Installation
kit:
AW1
Allen wrench for crossbar
AW2
Allen wrench for control unit
cbc
cap for crossbar fixing holes
cf
key of control unit lock
ck
screwdriver for upper connectors
K
on/off key
pcc
cap for photocell connections cover
PH
Phillips screwdriver (photocell)
vc
control unit mounting screw
PC
Protection
covers:
ccp
protection cover of
CU control unit and
C1 crossbar
Pictures of main components
Positioning the columns
Place F spacers on the floor as illustrated in the figure below.
Extract one column from the packaging and place it on the
F
spacers.
Extract
G
supports from the packaging and place them on the floor as illustrated in the figure
below. Place the column on the
G
supports.
Extract the second column from the packaging and place it on the
F
spacers.
Extract
G
supports from the packaging and place them on the floor.
Place the TX - RX columns as illustrated in the figure below (
connection module of the base
facing the ceiling
).
RX
TX
RX
TX
303-670-1099