PSA - Power Supply Adapter
Standard version:
protection degree: IP30 (IEC60529).
Input voltage: 100-240 V~, -10% / +15%. Dimensions: 145mm x 76mm x 45mm (LxWxH). Weight: 0,9 kg. Cable length:
input side: 3m. output side: 2m. Available input plugs: CEE, UL 15P, UL l5-15P, UK.
OPTION]
Metal case sealed version: protection degree: IP67 (IEC60529). Input voltage: 100…240V ~, -10/+15%,
47…63 Hz. Dimensions: 210mm x 68mm x 40mm (LxWxH). Weight: 1.3 kg. Cable length: input side: 2m; output side:
2m. The input side cable is not fitted with plug, to allow passing it inside conduits.
AA - Archway
The archway consists of two treated panels or columns containing the windings and the
connectors to the control unit. A special protective boot renders the base of the archway
waterproof, and therefore fully insulated even in the event of wet floors.
Parts of the archway
AA
:
TX
Transmitter antenna
UPC
upper protection cover
LCM
Lower Connection Module with on/off switch
UCM-TX
Upper Connection Module of TX antenna
Ph
Photocells for transit counting (options on column version). Two versions available: 2-
beam (standard) and 4-beam (high precision).
The photocell system is composed of two photocell modules (
P1, P2
), built into the
Transmitter Antenna, and two retroreflectors (
R1, R2
), built into the Receiver Antenna.
They allow counting of people passing through the archway.
LBL
Label with reference data:
MODEL/TYPE Model
SERIAL NUMBER Serial Number
MAC
address (with Ethernet interface only)
RX
Receiver
antenna
UPC
upper protection cover
UCM-RX
Upper Connection Module of RX antenna
Rf
Reflectors for transit counting (options on column version)
C1
crossbar fitted with holes for mounting the control unit
C2
crossbar without holes (panel shape version)
K
ON/OFF special key
Indicators and commands located in the archway
LINE
power indicator (lit on when I/O switch is set to ‘I’).
additional power indicator
entry pacing lights: green light – enter the archway; red light - wait
zone indication light bar: in case of an alarm, the bar indicates the position of the metal
mass intercepted inside the archway.
I / O
Anti-tamper on/off switch, activated using special key
K
11
low battery sounder (only with emergency battery option)
Connections located in the archway
LCM
Lower Connection Module:
30Vdc
power-supply input connector
|0|0|
9-pin
serial communication port (pin1: reserved, +30Vdc output; pin2: data in; pin3: data out; pin5:
ground; all other pins: reserved)
LAN
Ethernet port (only with Web Server and Logger option)
type-A host USB port (only with Web Server and Logger option)
micro-B device USB port (reserved, only with Web Server and Logger option)
UCM-TX
Upper Connection Module of TX antenna:
MD-TX
control unit-antenna connections
CNT-TX
auxiliary connector (for advanced functions)
PS/COM
serial communication port and power supply input (identical to
|0|0|
port
)
BAT
emergency battery connector (panel shape version only)
RJ
Ethernet port (with Web Server and Logger option installed, column-shape only)
USB port (with Web Server and Logger option installed, column-shape only)
CAM
supply output for accessory devices (with Ethernet option installed, column-shape only)
UCM-RX
Upper Connection Module of RX antenna:
MD-RX
control unit-antenna connections
CNT-RX
auxiliary connector (for advanced functions)