6. Maintenance
•
The FSP 600 DC Fast Charger is cooled by forced air. Please keep charger in a
ventilated location and do not block the air vents of the DC Fast Charger .
•
Please clean or replace the air filters regularly to ensure the DC Fast Charger
works properly.
•
The housing was made of welding process and surface painting. It is necessary to
keep the exterior clean all the time. It’s easy to get rusty if not keeping the exterior
clean especially in corrosion sensitive environment. Slightly rusty will not affect
charger performance, but if charger is serious rusty during or exceed the warranty
period, please contact local vendor for instruction.
•
Clean the FSP 600 DC at least three times a year, keep the exterior clean at all
times.
•
Clean the outside of the cabinet with damp cloth or wet cotton towel, only use
low-pressure tap water and cleaning agents with PH level between 6 to 8.
•
Do not apply high-pressure water jets.
•
Do not use cleaning agents with abrasive components and do not use abrasive
tools. Improper cleaning agents might spoiled coating, painting, surface, bright-
ness and durability of all exterior parts.
•
If there is water intruding into the FSP 600 DC then please cut off the power
source immediately and contact TurnOnGreen for repair.
•
Please make sure the charging connector is returned to the holder of the charging
connector after charging to prevent damage.
•
If there is damage to the charging connector, charging cable or holder of the
charging connector then please contact TurnOnGreen .
•
When using the FSP 600 please handle properly. Do not strike or scrape the cabi-
net or screen.
•
If the enclosure or screen is broken, cracked, open or shows any other indication
of damage then please contact TurnOnGreen .
6.1 General Maintenance
WARNING:
Danger of electrical shock or injury. Turn OFF power at the
panelboard or load center before working on the equipment or remov-
ing any component. Do not remove circuit protective devices or any
other component until the power is turned OFF.
•
Disconnect electrical power to the FSP 600 before any maintenance work to
ensure it is separated from the supply of AC mains. Failure to do so may cause
physical injury or damage to the electrical system and charging unit.