The product must be connected to a grounded, metal, permanent wiring system.
Connections shall comply with all applicable electrical codes. Recommend the
ground resistance be less than 10Ω.
•
Ensure no power is connected at all times when installing, servicing, or maintain-
ing the charger.
•
Use appropriate protection when connecting to main power distribution network.
•
Use appropriate tools for each task.
3.2 Grounding and Safety Requirement
CAUTION:
The disconnect switch for each ungrounded conductor of
AC input shall be provided by installation contractor or technician in
accordance with the National Electric Code, ANSI/NFPA 70.
CAUTION:
A cord extension set or second cable assembly shall not be
used in addition to the cable assembly for connection of the EV to the
EVSE.
NOTICE
It is recommended to conduct WI-Fi and 4G signal strength while
charger installation. The RSSI (Received Signal Strength Indication)
value is considered as good as higher than -65dBm. Poor connec-
tion quality might interrupt charging process or data transaction.