Setting
RFID channels – process input data
94
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Designation
Meaning
Write fragment no. (WFN)
If the data to be written exceeds the size of the write data memory, the data is
divided in max. 256 fragments. The fragments are numbered consecutively from
1…255. From fragment number 256 numbering starts again at 1.
The sending of a fragment is confirmed by the device if the write fragment num-
ber appears in the process input data. After the confirmation the next fragment
is written.
0: No fragmentation
In Idle mode the size of the fragments is stated. With a Write command the num-
ber of fragments containing data is stated.
TP1…TP32
Tag in detection range of the connected read/write head (only available in HF
bus mode)
Read data
User-defined read data
Содержание TBEN-L4-4RFID-8DXP