Setting
RFID channels – overview of commands
132
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Example: Direct command in UHF applications (set output power)
Read the set power from the RAM of the read/write head.
Request
Loop counter
0
Command code
0x0060
Read/write head address
0
Length UID/EPC
0
Start address
0
Length
5
Command timeout
200
Write fragment no.
0
Read fragment no.
0
Write data
0x09 8A 4A 03 01
Change output power: Write “30 dBm” power in the RAM and flash memory of the read/
write head. The sixth byte of the write data sets the power in dBm as a hexadecimal
value.
Request
Loop counter
0
Command code
0x0060
Read/write head address
0
Length UID/EPC
0
Start address
0
Length
6
Command timeout
200
Write fragment no.
0
Read fragment no.
0
Write data
0x09 8A 3C 03 01 1E