Commissioning TBEN-L...-PLC-... as Modbus TCP Slave
Properties
Max. number of input registers
1024
Max. number of holding registers
1020
Configuring the Modbus TCP Slave
The Modbus_TCP_Slave_Device from Turck is used.
ü
The Ethernet interface is configured.
Add the Modbus_TCP_Slave_Device to the Ethernet interface using the "Add Device"
function and configure it.
Therefore define the number of in- and output registers (input and holding registers)
which have to be exchanged with the higher-level Modbus TCP-master.
Fig. 45: Configuring the Modbus TCP Slave