27
V01.01 | 2016/10
9.1
Set via teach adapter
Select output
➤
➤
Select switching output 1: Press and hold down the pushbutton on the adapter to GND for
2…7 s.
➤
➤
Select output 2: Press and hold down the pushbutton on the adapter to GND for 8…13 s.
Set the switching point
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Select the switching output.
➤
➤
Place the object for the switching point accordingly.
➤
➤
Store the switching point: Press and hold down the pushbutton on the adapter to GND for
2…7 s.
➤
➥
The switching point has been taught in successfully if the green LED flashes for 1.5 s at a
frequency of 5 Hz.
Window function — setting the switching range
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Position the object for the 1st switching point.
➤
➤
Select the switching output.
➤
➤
Store the 1st Store the switching point: Press and hold down the pushbutton on the adapter
to GND for 8…13 s.
➤
➤
Position the object for the 2nd switching point.
➤
➤
Store the 2nd Store the switching point: Press and hold down the pushbutton on the adapter
to GND for 2…7 s.
➤
➥
The switching points have been successfully taught in if the green LED flashes for 1.5 s at a
frequency of 5 Hz.
Window function — switching between hysteresis and window
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Position the object at any point in the sensing range.
➤
➤
Press and hold down the pushbutton on the adapter to GND for 8…13 s.
➤
➤
Press and hold down the pushbutton on the adapter to GND for 8…13 s.
➤
➥
The window has been taught in successfully if the green LED flashes for 1.5 s at a frequency of
5 Hz.
➤
➥
The hysteresis has been taught in successfully if the yellow LED flashes for 1.5 s at a frequency
of 5 Hz.
Inverting the output function (NO/NC)
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Select the switching output.
➤
➤
Press and hold down the pushbutton on the adapter to GND for 14…19 s.
➤
➥
The output function has been successfully inverted as an NO contact if the green LED flashes
for 1.5 s at a frequency of 5 Hz.
➤
➥
The output function has been successfully inverted as an NC contact if the green LED flashes
for 1.5 s at a frequency of 5 Hz.