14
Hans Turck GmbH & Co. KG | T +49 (0)208 4952-0 | F +49 (0)208 4952-264 | [email protected] | www.turck.com
Product description
Window function
The start and end point of the switching window can be set for the outputs. The switching win-
dow must be within the sensing range.
0
1
SP1
SP2 max
detection range
blind
zone
out
Fig. 6: Window function — behavior of the switching output
Hysteresis function
When using the hysteresis function, a switching window is taught in that is defined by two
switching points. The switching outputs have the following behavior as outputs: If an object is
moved away from the sensor, the switching output is switched on for as long as the object is
located between the beginning of the sensing range and the 2nd switching point. If the object
passes the 2nd switching point, the switching output is switched off. If an object is moved
towards the sensor, the switching output is switched on for as long as the object is located
between the end of the sensing range and the 1st switching point. If the object passes the 1st
switching point, the switching output is switched on.
0
1
switch-on
switch-off
detection range
blind
zone
out
out
Fig. 7: Hysteresis function — behavior of the switching output