Setting
RU200-CK40 – Setting via a teach adapter
26
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Window function – switching between hysteresis and window
Choice:
window /
hysteresis*
Out2
Out1
GND/T1 > 8 s
13 s
LED GN 2 × 1 Hz
GND/T1 > 8 s
13 s
LED YE 2 × 1 Hz
Measure and save
Fail
LED GN/YE
1.5 s × 5 Hz
Hysteresis
LED YE
1.5 s × 5 Hz
GND/T1 > 2 s
7 s
LED GN 1 × 1 Hz
Window
LED GN 1.5 s × 5 Hz
GND/T1 > 8 s
13 s
LED GN 1 × 8 Hz
Select
Normal
operation
* Set window
function before
Fig. 40: Window function – switching between hysteresis and window
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
Select the switching output.
Press and hold down the pushbutton on the adapter to GND for 14…19 s.
a
The output function has been successfully inverted as an NO contact if the green LED
flashes for 1.5 s at a frequency of 5 Hz.
a
The output function has been successfully inverted as an NC contact if the yellow LED
flashes for 1.5 s at a frequency of 5 Hz.