![turck RU CK40 Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/turck/ru-ck40-series/ru-ck40-series_instructions-for-use-manual_1181599034.webp)
Setting
RU200-CK40 – Setting by manual bridging (shorting)
34
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Window function – setting the switching range
Window function
Out2
Out1
GND/T1 > 8 s
13 s
LED GN 2 × 1 Hz
GND/T1 > 8 s
13 s
LED YE 2 × 1 Hz
Measure and save
SP1
Fail
LED GN/YE
1.5 s × 5 Hz
GND/T1 > 2 s
7 s
LED GN 1 × 1 Hz
GND/T1 > 2 s
7 s
LED GN 1 × 2 Hz
Measure and save
SP2
OK
LED GN
1.5 s × 5 Hz
Normal
operation
U
B
/T2 > 2 s
LED YE
1 × 8 Hz
Cancel
Fig. 48: Window function – setting the switching range
Position the object for switching point 1.
Store switching point 1: Bridge pin 3 (BU) with pin 5 (GY) for 8…13 s.
Position the object for switching point 2.
Store switching point 2: Bridge pin 3 (BU) with pin 5 (GY) for 2…7 s.
a
The switching points have been successfully taught in if the green LED flashes for 1.5 s at
a frequency of 5 Hz.
Содержание RU CK40 Series
Страница 1: ...Your Global Automation Partner Instructions for Use RU CK40 RU CP40 Ultrasonic Sensors...
Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...
Страница 55: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100001118 2021 06 100001118...