Setting
RU200-CK40 – Setting via a teach adapter
28
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Setting operation as a retroreflective sensor
Retroreflective
sensor
UB/T2 > 20 s
LED YE 1 × 1 Hz
Position sensor
Fail
LED GN/YE
1.5 s × 5 Hz
OK
LED GN
1.5 s × 5 Hz
Normal
operation
Fig. 42: Setting operation as a retroreflective sensor
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
Position the reflector in the detection range.
Press and hold down the pushbutton on the adapter to U
B
for at least 21 s.
a
The sensor is set successfully as a retroreflective sensor if the green LED flashes for 1.5 s at
a frequency of 5 Hz.