Installing
NOTE
When using more than one ultrasonic sensor in an application: Avoid the overlap-
ping of sonic cones.
An overlap can occur if two sensors are mounted closer than 2500 mm apart.
The sensors can be mounted in any direction.
Clean the mounting surface and its surroundings.
When using a mounting aid: Fasten the sensor in the mounting aid.
Install the sensor or mounting aid at the intended position.
Ensure that the rear plug connector is accessible.
Mount the sensor so that the blind zone is clear of any relevant objects (see wave
patterns or technical data).
0
-150
-100
-50
50
100
150
0
20 40 60 80 100 110 120 140 160 200
cm
100x100 mm
ø 27 mm
Fig. 11: Wave pattern